Section 07 41 00 Metal Roof Panels

Part 1 - General

    • 1.1

      Description

      • A.

        Section Includes preformed metal roof and wall panel system including closures, related sheet metal trim, fasteners, and sealants

    • 1.2

      Related Sections

      • A.

        Division 7 Section - Sheet Metal Flashing and Trim

    • 1.3

      Submittals

      • A.

        Shop Drawings by manufacturer only, including the following:

      • B.

        Product Data

1.

Manufacturer's data sheet including all accessories

C.

Samples

1.

12" long

section

of specified

panel width

and finish

  • D.

    Design Test Reports - must meet or exceed design and performance criteria

    • 1.

      ASTM E1592

  • E.

    Sample Warranties

    • 1.

      Specified Sample Finish Warranty

    • 1.4

      Installer Qualifications

      • A.

        5 years experience in the installation of metal roof systems

    • 1.5

      Delivery, Storage, and Handling

      • A.

        Protect components using best practices to prevent abrasion damage, mechanical abuse,

staining discoloration, or corrosion during manufacturing, shipment and storage.

B.

Secure panels where they are protected from wind and moisture, while allowing proper drainage and air circulation

  • C.

    Any unsatisfactory components will be rejected and/or reproduced to meet quality criteria

    • 1.6

      Job Conditions

B.

Verify acceptable storage loads on roof slopes

C.

Precise location of all roof penetrations shall be verified prior to final roof layout

A.

or installed

stored

to

prevent damage

to

or adjoining trades

Coordinate work with components