X hits on this document

862 views

0 shares

0 downloads

0 comments

193 / 324

  • 12.

    Threshold: Manufacturer's standard two-piece type of extruded aluminum, mill finish with safety ribs, 4 inches wide by '/2 inch height; ribbed extruded vinyl sweep across door bottom.

  • 13.

    Frame finish: Field-applied.

  • 14.

    Wood casings: Specified in Section 06200

C. Therma-Tru Light Commercial and Multi-Family Steel Fames-Secura-Fit.

  • 1.

    Acceptable product: Therma-Tru Secura-Fit Steel Frame

  • 2.

    Construction: 16 gauge galvanized steel conforming to ASTM A 653, commercial quality, A40 coating, and as follows:

  • 3.

    Profile: L-shape profile for 1-3/4 inch door thickness, flat face punched with elongated fastener holes, primed wood stops kerfed for weather-strip.

  • 4.

    Corners: Butted at intersections of head and jambs.

  • 5.

    Hardware preparation: Frames prepared for hardware, reinforced as follows:

    • a.

      Hinges reinforced for 4- inches by 4- inches located in accordance with manufacturers specifications.

b

c.

d

. Strike: Reinforcement for 2-3/4 tee strike, integral with frame, located in accordance with manufacturers specifications Surface-mounted hardware: Concealed reinforcement of minimum 16 gauge. . Therma-Tru provided for other door hardware as

specified in Section 08710.

  • 6.

    Weatherstrip Manufacturer's standard foam filled compression weatherstrip, installed in kerf of applied stop.

  • 7.

    Threshold: Manufacturer's standard two-piece type of extruded aluminum, mill finish with safety ribs, with interlocking extruded sill component, adjustable for wall thickness variation; ribbed extruded vinyl sweep across door bottom.

  • 8.

    Frame finish: Field Finish.

  • 11.

    Wood casings: Specified in Section 06200

2.06

RELATED MATERIALS

A. Related materials: Refer to other sections

    • 2.07

      SOURCE QUALITY

      • A.

        Source quality: Obtain metal door and frame products from manufacturers Inspected and audited by third party inspection agencies such as Intertek Services and the National Accreditation Management Institute.

Section 3A - 8