A.

Design and Performance Requirements:

1.

Window units shall be designed to comply with ANSI 1AAMA 1NWWDA 101

II.S.2-97 and 101 II.S. 21 NAFS-02

    • a.

      Single Hung: (H-LC50) (H-LC30)

    • b.

      Transom: (TR-C50)

    • c.

      Picture: (F-C50)

  • 2.

    Air leakage shall not exceed the following when tested at 1.57 according to ASTM E 283: .0.3 cfm per square foot of frame.

  • 3.

    No water penetration shall occur when units are tested at the following pressure according to ASTM E 547:

a. b. c.

Single Hung: (H-LC50

7.5 psf) (H-LC30 -

Transom: (TR-C50-7.5 psf) Picture: (F-C50-7.5 pst)

4.5 pst)

4.

Units shall be designed to comply with ASTM E330 for structural performance when tested at the following pressures:

  • a.

    Single Hung: (H-LC50 - 75 psf) (H-LC30 - 45 psf)

  • b.

    Transom: (TR-C50-75 psf)

  • c.

    Picture: (F-C50-75 psf)

1.5 SUBMITTALS

  • A.

    Shop Drawings: Submit shop drawings under provisions of Section 01 3323.

  • B.

    Product Data: Submit catalog data under provisions of Section 01 3323.

  • C.

    Samples:

    • 1.

      Submit corner section under provisions of Section 01 33 23.

    • 2.

      Include glazing system, quality of construction, and specified finish.

  • D.

    Quality Control Submittals: Submit manufacturer's certifications indicating compliance with specified performance and design requirements under provisions of Section 01 33 23.

1.6 QUALITY ASSURANCE

A.

Regulatory Requirements: Emergency Egress or Rescue: Comply with requirements for sleeping units of [IBC International Building Code] [BOCA Basic Building Code] [Southern Building Code] [Uniform Building Code]

[

J.

1.7 DELIVERY

    • A.

      Comply with provisions of Section 01 6500.

    • B.

      Deliver in original packaging and protect from weather.

      • 1.8

        STORAGE AND HANDLING

        • A.

          Prime or seal wood surfaces, including surface to be concealed by wall construction, if more than thirty (30) days will

expire between delivery and installation.

  • B.

    Store window units in an upright position in a clean and dry storage area above ground and protect from weather under provisions of Section 01 6600.

    • 1.9

      WARRANTY

  • A.

    Windows shall be warranted to be free from defects in manufacturing, materials, and workmanship for a period of ten

    • (10)

      years from purchase date.

  • B.

    Window glass shall be warranted to be free from defects in manufacturing, materials and workmanship for period of twenty (20) years from the purchase date.