X hits on this document

821 views

0 shares

0 downloads

0 comments

296 / 324

A

Tract B ofthe Villa Alegre Development

investigation. If desired, Vinyard & Associates, Inc. will perform an environmental audit of the site.

2.0

PROPOSED CONSTRUCTION

We anticipate multi-family housing

the and

site will be a recreation

developed with one-story and two-story

center.

The

proposed

buildings

will

be

constructed

utilizing

conventional

wood-frame

construction.

The

ground

floor

will

be a conventional concrete slab-on-grade. No basements are anticipated. The maximum column and bearing wall

or below grade structures loads (dead plus live) are

not anticipated to exceed 10 kips and 2.4 kips structure loads or configuration differ from those should be notified.

per linear foot, indicated in this

respectively. If report, this office

Final site grading plans were not available during preparation of this report. We anticipate that limited cut/fill earthwork will be required to develop the site.

3.0

SITE CONDITIONS

The site is bound to the north by West San Francisco Street and to the south by West Alameda Street. The site is bound to the east by existing residences and to the west by existing homes.

V &A Project No.: 09-].·102