ET500

Two-part Epoxy Technical Information Sheet

ET500A

ET500B

Chemical Type

Epoxy Resin

Amine Hardener

Colour

Colourless

Colourless

Viscosity

15,000 mPa.s

22,500 mPas

Density

1.2

1.0

Permabond ET500 will bond to a wide variety of surfaces such as wood, metal and ceramics, including many plastic and composite materials. It cures rapidly to give a handling strength in approximately 5 minutes at room temperature.

Physical Properties

Mix Ratio

By volume

1:1

Gap Fill

Up to 2mm

Usable Life

Mixed @ 20°C

3 minutes

Working

4-6 minutes

Strength

Full Strength

24 hours

Typical Performance

Surface Preparation Surfaces should be clean, dry and grease-free before applying the adhesive. Permabond Cleaner A is recommended for the degreasing of most surfaces. Some metals such as aluminium, copper and its alloys will benefit from light abrasion with emery cloth (or similar), to remove the oxide layer.

Adhesive Application

  • If dispensing from a cartridge, ensure back pistons

are level before using the adhesive. Attach static mixing nozzle and apply using a dispensing gun.

  • For bulk application ensure the resin and hardener

are thoroughly mixed and in the correct proportion.

  • Apply the adhesive to one surface and avoid

entrapping air.

  • Assemble parts applying sufficient pressure to ensure

the adhesive spreads to cover the entire bond area.

  • Use a jig / clamp to prevent parts moving during cure.

  • It is advisable not to disturb the joint until the

adhesive is fully cured.

  • Permabond ET500 will cure at temperatures as low

as 0°C but care must be taken to ensure the surfaces are not coated with condensation.

Shear Strength

Peel Strength

Shore D Hardness

Elongation at break

ASTM D-1002

ISO4578

73

Shelf Life

Stored in original unopened

7%

containers

12 months

14 MPa (steel)

45 N/25mm

Storage and Handling

Storage Temperature

5 to 25°C

Service Temperature*

  • -

    40 to +80°C

*Higher temperatures may be endured for short periods providing the parts are not unduly stressed.

Users are reminded that all materials, whether innocuous or not, should be handled in accordance with the principles of good industrial hygiene. Full information can be obtained from the Material Safety Data Sheet.

Contact Permabond: Europe: Tel. +44 (0)1962 711661 UK Helpline: 0800 975 9800 Deutschland: 0800 10 13 177 France: 0805 11 13 88 info.europe@permabond.com

US:

Asia:

Tel. 00 1 732-868-1372 Helpline: 800-640-7599 info.americas@permabond.com Tel. 00 886 939 49 3310 info.asia@permabond.com

www.permabond.com

The information given and the recommendations made herein are based on our experience and are believed to be accurate. No guarantee as to, or responsibility for, their accuracy can be given or accepted, however, and no statement herein is to be treated as a representation or warranty. In every case we urge and recommend that purchasers, before using any product, make their own tests to determine, to their own satisfaction, its suitability for their particular purposes under their own operating conditions.

Document info
Document views2
Page views2
Page last viewedThu Oct 20 19:49:13 UTC 2016
Pages1
Paragraphs82
Words475

Comments