Metal Edge Detail – Mineral Surfaced Applications Base sheet must extend over fascia a min. of 2". A min. 9" wide strip of flashing membrane (Flintlastic APP modified bitumen) should then be applied to the base sheet, flush with the roof edge and extending 9" onto the field of the roof.

Appropriate edge metal (min. 26 gauge, primed) must be properly installed and secured (in two rows, spaced every 6" staggered, fasteners placed every 3"). Finally the mineral surfaced Flintlastic APP modified bitumen cap sheet is in- stalled securely over the 4" edge metal face (continuous from the field of the roof).

Metal edge details, Flintlastic GTA granule surfaced APP Modified Bitumen Membrane

Metal Edge Detail – Smooth Surfaced Applications Base sheet must extend over fascia a min. of 2". Next, the smooth surfaced Flintlastic APP modified bitumen field membrane is installed, cut flush with the roof edge. Appropriate edge metal (min. 26 gauge, primed) must be properly installed and secured. A min. 10" wide strip of Flintlastic APP modified bitumen smooth surfaced membrane should then be applied over the metal (flush to the roof edge and extending a min. of 6" onto the field of the roof past the portion of the metal which rests on the field membrane).

Metal edge detail, Flintlastic STA smooth surfaced APP Modified Bitumen Membrane