Continuous overvoltage protection (Vsup) ................................up to 40 V max

Reversed-voltage protection .............None Current limiting ................................None

Short-circuit protection.....................Indefinitely protected when a channel is shorted to COM or to a voltage up to Vsup

Trip current for one channel

With all other channels at rated current............................3 A typ

With all other channels off .........5 A typ Vsup current consumption..................28 mA max

Maximum update rate.......................40 µs max Propagation delay .............................500 µs max