Kim Hotstart Model Numbers

Oil Capacity

Volts Watts

1/2” N.P.T.With a 4” Probe Length

3/4” N.P.T. With 4 7/8” Probe Length

a

1” N.P.T.With a 5 3/8” Probe Length

2 Quarts

12

75

OW207900-012

OW407900-012

or Less

24

75

OW207900-024

OW407900-024

Amps

Watts Per Square Inch

6.3 3.1

1/2”are all 14.7WSI 3/4”are all 7.3WSI

DC Oil Heaters

12 and 24 volt

2 to 6 Quarts

24

125

OW212900-024

5.2

24.6 WSI

1 to 5 Gallons

12 24

150 150

OW415900-012 OW415900-024

OW615900-012 OW615900-024

12.5 6.3

3/4”are all 14.6WSI 1”are all 10.7WSI

5 to 15 Gallons

12 24

300 300

OW430900-024

OW630900-012 OW630900-024

25.0 12.5

3/4”are all 29.3WSI 1”are all 21.4WSI

15 to 30 Gallons

24

500

OW650900-024

20.8

35.7 WSI

12 VOLT/24 VOLT DC CONTROL BOXES

25 Amps

12V

JBMC330DC-12V

Maximum

24V

JBMC330DC-24V

12 Volt and 24 Volt DC oil heaters can be powered directly from the battery, but it will drain the battery very rapidly unless charged by an alternator or generator.

NOTE: Heater amperage as shown in the table above will determine the life of the

= 8 Hours

When used with a thermostat control, all DC oil heaters must use a DC relay

battery — (Amps x Hours = Amp hours).

Example: A 12.5 Amp heater will completely drain a 100 Amp-hour battery in 8 hours.

100 Amp x hour 12.5 Amp

+

Magnetic Contactors

-

12 or 24 VDC

DIT

C1 COIL

C1

C1

Oil Heater

Weathertight

Temp. Range

Thread

Model Number

On

Off

Size

Thermostat

Heaters with Y-type harness and thermostat

Lube oil temperature controls hold lube oil at the desired temperature and protect the oil from overheating if the heater is energized while the engine is hot or running.

Kim Hotstart recommends using thermostats with all lube oil heaters to protect the oil from overheating.

Lube oil heaters must always be installed in the sump with the entire heater submerged below the oil level at all times.The sensing unit can be changed without draining the sump.

DIT68

60°F

80°F

1/2”N.P.T.

DIT810

80°F

100°F

1/2”N.P.T.

DIT1012

100°F

120°F

1/2”N.P.T.

DIT1214

120°F

140°F

1/2”N.P.T.

.600

.5 NPT

3' 16-3 HPN Cord

1.75

3.375

1.625 Probe Depth

Temperature Controls

Weathertight

Weathertight models are furnished with a 3 ft. 16/3 HPN power cord.

Customer Support: (509) 536-8660

Toll-Free FAX: (800) 224-5550

www.kimhotstart.com

19

Document info
Document views105
Page views111
Page last viewedSun Dec 11 06:34:29 UTC 2016
Pages24
Paragraphs1912
Words7545

Comments