MARTECH RCD PRO

6.3 RCDPRO_RCD500

Module designed to work with radios RCD 500 CQ-EV1572 by Matsushita

Required equipment:

  • -

    Martech CLIP with RCD PRO activation

  • -

    12V/3A power supply to power the radio

      • 6.3.1

        Wiring diagram for RCD500

Test points are located on the PCB at the bottom side of the radio.

For the correct operation it requires only: the power connection and radio signals from PORT1 and PORT2 of the CLIP by the following scheme (pinout is also available from the same application - Help tab):

PORT1 pin 4 - RST testpoint PORT1 pin 5 - CNVSS testpoint

PORT2 pin 4 - TXD testpoint PORT2 pin 5 - RXD testpoint PORT2 pin 7 - GND testpoint