X hits on this document

119 views

0 shares

0 downloads

0 comments

26 / 50

Installing the Unit

WARNING: Thermo King requires a 3 point lifting bar to safely lift and install units. A lifting bar can be made from the drawings provided (See Lifting Bar Dimensions).

WARNING: The use of a safe working platform for truck unit installations is recommended to prevent damage to the unit and possible personal injury.

WARNING: Use only locking hooks (Detail A) to prevent damage to the unit and possible personal injury.

  • 1.

    Use a 3 point lifting bar to carefully lift the unit up to the truck opening.

  • 2.

    Install four M12 (1/2 in. Grade 5) mounting bolts through the wall of

the truck box.

NOTE: The mounting bolts should protrude 63.5 mm (2.50 in.) full thread from the front wall (Detail B).

IMPORTANT: DO NOT INSTALL ANY COMPRESSIBLE WASHERS OR OTHER MATERIALS BETWEEN THE UNIT AND THE TRUCK!

  • 3.

    The four 4.8 mm (0.188 in.) mounting washers provided must be used between the frame of the unit and the locking nut holding the unit to the front wall of the truck.

  • 4.

    Torque to 81.4 Nm (60 ft. lbs.).

26

Document info
Document views119
Page views119
Page last viewedTue Dec 06 15:20:27 UTC 2016
Pages50
Paragraphs453
Words4996

Comments