X hits on this document

PDF document

REGULATION FOR THE MANDATORY REPORTING OF GREENHOUSE GAS EMISSIONS - page 42 / 137

403 views

0 shares

0 downloads

0 comments

42 / 137

  • (J)

    Fugitive SF6, in kilograms, emitted from equipment that is located at the facility and that the operator is responsible for maintaining in proper working order. Operators of multiple facilities or operators subject to the requirements in section 95111(b)(2)(A) may aggregate SF6 emissions for all sources or any subset of sources;

  • (K)

    For facilities located inside California, wholesale sales (MWh) exported directly out-of-state, if known, that are additional to electricity transactions reported as specified in section 95111(b)(2)(E). Sales shall be aggregated by counterparty and measured at the busbar. The operator shall report the region of destination as Pacific Northwest (PNW) or Southwest (SW).

  • (2)

    For each generating unit operators shall include:

    • (A)

      Generating unit ID designated by ARB, nameplate generating capacity (MW), and net power generated (MWh);

  • (B)

    Fuel consumption by fuel type reporting in units of million standard cubic feet for gases, gallons for liquids, short tons for non-biomass solids, and bone dry short tons for biomass-derived solid fuels;

  • (C)

    CO2, N2O, and CH4 emissions from fuel combustion in metric tonnes as specified in section 95111(c)-(d) by fuel type;

    • (D)

      For units of facilities located inside California, wholesale sales (MWh) exported directly out-of-state by generating unit if applicable and as specified in section 95111(a)(1)(K).

  • (3)

    Aggregation of Multiple Units. If a facility lacks the necessary metering or monitoring equipment to measure data individually for each generating unit, the operator may report data on an aggregated basis for multiple units that combust the same fuel type.

  • (4)

    Cogeneration Facilities. Operators of generating facilities with cogeneration systems subject to the requirements of this article shall also meet the requirements of section 95112.

  • (5)

    Out-of-State Facilities. Operators of out-of-state generating facilities that are not subject to any of the mandatory reporting requirements of this article may voluntarily submit a greenhouse gas emissions data report that meets applicable requirements in this article for generating facilities.

(6)

Asset Owning/Asset Controlling Suppliers. An asset owning or asset controlling supplier may voluntarily request that ARB assign a supplier-

42

Document info
Document views403
Page views403
Page last viewedFri Dec 09 22:09:41 UTC 2016
Pages137
Paragraphs3283
Words41863

Comments