emission calculations from stationary combustion for inclusion in the greenhouse gas emissions data report.

  • (1)

    Natural Gas. Operators of generating facilities or units that combust natural gas and are subject to the requirements of 40 CFR Part 75 shall include Part 75 CO2 emissions data for the report year. Operators may elect to use revenue fuel meters to conduct quality checks on generating unit level information. For facilities or units that combust natural gas but are not required to report CO2 emissions under 40 CFR Part 75, the operator shall calculate and include CO2 emissions using methodologies provided in:

    • (A)

      Sections 95125(c)-(d) or (g) if the high heat value is > 975 and < 1100

Btu per scf or;

  • (B)

    Section 95125(d) or (g) if the high heat value is < 975 or > 1100 Btu per scf.

    • (2)

      Coal or Petroleum Coke.

  • (A)

    Operators of generating facilities or units that combust coal or petroleum coke and are subject to the requirements of 40 CFR Part 75 shall include Part 75 CO2 emissions data for the report year, or CO2 emissions based on alternative equations and specifications by fuel type provided in 40 CFR Part 75, Appendix G;

  • (B)

    If the generating facility or unit is not subject to the requirements in 40 CFR Part 75, the operator of the generating facility shall calculate and include CO2 emissions using methods specified in section 95125(d) or section 95125(g).

  • (3)

    Middle Distillates, Gasoline, Residual Oil, or Liquid Petroleum Gases (LPG).

    • (A)

      If a generating facility or unit combusts middle distillates (such as diesel, fuel oil, or kerosene), gasoline, residual oil, or LPG (such as ethane, propane, isobutene, n-Butane, or unspecified LPG) and is subject to the requirements of 40 CFR Part 75, the operator of the facility shall include Part 75 CO2 emissions data for the report year;

    • (B)

      If the generating facility or unit is not subject to the requirements of 40 CFR Part 75, the operator shall calculate and include annual CO2 emissions using the methods specified in sections 95125(c)-(d) or (g).

  • (4)

    Refinery Fuel Gas, Flexigas, or Associated Gas. If a generating facility combusts refinery fuel gas, flexigas, or associated gas, the operator shall