§ 95112. Data Requirements and Calculation Methods for Cogeneration Facilities.

  • (a)

    Greenhouse Gas Emissions Data Report. The operator of a cogeneration facility specified in section 95101(b) shall include the following information in the greenhouse gas emissions data report for each report year. The operator of a cogeneration facility that is a self-generation facility with nameplate generating capacity less than ten megawatts and is not otherwise subject to the requirements of this article as specified in Section 95101(b)(1)-(6) and (8), may elect to submit an abbreviated emissions data report as specified in Section 95112(c).

    • (1)

      Facility level and generating unit information as specified in sections

95111(a)(1)-(3) as applicable.

  • (2)

    Cogeneration System:

    • (A)

      Prime mover of each cogeneration system.

    • (B)

      Identification of the cogeneration facility as a topping cycle or bottoming cycle plant

    • (C)

      Description of waste heat technology, including nameplate data for waste heat boiler, waste heat jacket heat exchanger, absorption chiller, and hot water heat exchanger

  • (3)

    Electricity Generation:

    • (A)

      Electricity sold wholesale (MWh)

    • (B)

      Electricity sold or provided directly to end-users (MWh) and end-user’s NAICS code

    • (C)

      Electricity consumed on-site for each report year (MWh)

    • (D)

      Efficiency of electricity generation, if known

  • (4)

    Thermal Energy Production:

    • (A)

      Total useful thermal output (MMBtu)

      • 1.

        Amount of thermal energy sold or provided to cogeneration thermal host (MMBtu) and customer’s NAICS code

      • 2.

        Amount of thermal energy from the cogeneration system consumed on-site for processes other than the cogeneration system for each report year (MMBtu)

    • (B)

      Input steam to steam turbine, if measured (MMBtu)

    • (C)

      Output of heat recovery steam generator (MMBtu)

    • (D)

      Fuel fired for supplemental firing in the duct burner of the heat recovery steam generator (MMBtu)

    • (E)

      Efficiency of thermal energy production, if known

  • (5)

    Distributed Emissions:

    • (A)

      Distributed emissions to thermal energy production (metric tonnes CO2)

55