c. Pegged components over SV 9,999 ppmv. The operator shall calculate VOC emissions for each screening period (e.g. month, quarter, year) as follows:

EVOCP-10

6 = CCi * PFiP-10 i=1

*t

Where: EVOCP-10 = VOC emissions for components pegged over SV 9,999 ppmv (kg/screening period) i = component type (1=valve, 2=pump seal, 3=others, 4=connector, 5=flange, 6=open-ended line)

CC PF = number of i components pegged over 9,999 ppmv = VOC emission factor (kg/hr) for component type i iP-10

i pegged over 9,999 ppmv (see Appendix A, Table 14) t = time component has been leaking (hours) – default value is time since last screening

d. Pegged components over 99,999 ppmv. The operator shall calculate VOC emissions for each screening period (e.g. month, quarter, year) as follows:

EVOCP-100

6 = CCi * PFiP-100 i=1

*t

Where: EVOCP-100

= VOC emissions for components pegged over

99,999 ppmv (kg/screening period)

i = component type (1=valve, 2=pump seal, 3=others, 4= connector, 5=flange, 6=open-ended line) C C i = n u m b e r o f i c o m p o n e n t s p e g g e d o v e r 9 9 , 9 9 9 p p m v P F i P - 1 0 0 = V O C e m i s s i o n f a c t o r ( k g / h r ) f o r c o type i pegged over 99,999 ppmv (see Appendix A, Table m p o n e n t

14) t = time component has been leaking (hours)- default value is time since last screening

4. The operator shall calculate and report methane emissions in the following manner:

n CH4 = (EVOC-0 1

  • +

    EVOC-LC

  • +

    [EVOCP-10

or EVOCP-100

]) * CFVOC

  • *

    0.001