operator shall select and operate the added devices pursuant to the requirements in 40 CFR Part 75.

(7)

If a facility does not have a continuous emissions monitoring system and the operator chooses to add one in order to measure CO2 concentrations, the operator shall select and operate the CEMS pursuant to the requirements in 4 0 C F R P a r t 7 5 . T h e o p e r a t o r s h a l l u s e C O 2 c o n c e n t r a t i o n s a n d f l u e g a s f l o w m e a s u r e m e n t s t o d e t e r m i n e h o u r l y C O 2 m a s s e m i s s i o n s u s i methodologies provided in 40 CFR Part 75, Appendix F. The operator shall report CO2 emissions for the report year in metric tonnes based on the sum of hourly CO2 mass emissions over the year, converted to metric tonnes. Operators who add CEMS under this article are subject to specifications in section 95125(g)(3)-(6), if applicable. n g

  • (h)

    Method for Calculating CO2 Emissions from Combustion of Biomass, Municipal Solid Waste, or Waste Derived Fuels with Biomass.

    • (1)

      The operator shall use the following method to calculate CO2 emissions in the report year from combustion of biomass solid fuels or municipal solid waste.

(A) CO2 emissions from combusting biomass or municipal solid waste shall be calculated using the following equation:

CO2 = Heat * CCEF * 3.664 * 0.001

Where: CO2 = Heat = CCEF =

CO2 emissions from fuel combustion, metric tonnes per year Heat calculated in section 95125(h)(1)(B), MMBtu per year Default carbon content emission factor provided in

Appendix A, kg carbon per MMBtu

    • 3.664

      = CO2 to carbon molar ratio

    • 0.001

      = Conversion factor to convert kilograms to metric tonnes

(B)

Heat content shall be calculated using the following equation:

Heat = Steam * B

Where Heat

=

Heat, MMBtu per year

Steam = Actual Steam generated, pounds per year

B

= Boiler Design Heat Input/Boiler Design Steam Output,

as Design MMBtu per pound Steam