X hits on this document

PDF document

REGULATION FOR THE MANDATORY REPORTING OF GREENHOUSE GAS EMISSIONS - page 96 / 137

315 views

0 shares

0 downloads

0 comments

96 / 137

C F 1 = C o n v e r s i o n f a c t o r e q u a l s 0 . 0 4 2 2 8 , l b s C H 4 / s c f C F 2 = C o n v e r s i o n f a c t o r e q u a l s 2 , 2 0 4 . 6 , l b s / m e t r i c t o n

(k) Method for Calculating Indirect Electricity Usage.

The operator of a facility that consumes electricity that is purchased or acquired from a retail provider or a facility they do not own or operate shall report electricity use and identify the provider(s) for all electricity consumed at the facility.

(1)

For each electricity provider, the operator shall sum electricity use (kWh) from billing records for the report year. If the records do not begin on January 1 and end on December 31 of the report year, but span two calendar years, the facility shall pro-rate its power usage according to the fraction of days billed for each month in each year using the equation shown.

Calculating electricity use for partial months:

Partial Month Electricity use (kWh) = (electricity use (kWh) in period billed / total number days in period billed) * (number of report year days in the period billed)

  • (2)

    The operator shall report by electricity provider the electricity consumed at the facility in kilowatt-hours (kWh).

    • (l)

      Method for Calculating Indirect Thermal Energy Usage.

The operator of a facility that consumes steam, heat, and/or cooling that is purchased or acquired from a facility that they do not own or operate shall report thermal energy use and identify the provider(s) for all thermal energy consumed at the facility.

(1)

For each thermal energy provider, the operator shall obtain data from the facility’s thermal use records, and sum this usage for the report year. If the records do not begin on January 1 and end on December 31 of the report year, but span two calendar years, the facility shall pro-rate its indirect thermal energy usage according to the fraction of days billed for each month in each year using the equation shown.

Calculating thermal use for partial months:

Partial Month Thermal use (Btu) = (thermal use (Btu) in period billed / total number days in period billed)

  • *

    (number of report year days in the period billed)

96

Document info
Document views315
Page views315
Page last viewedSun Dec 04 01:57:36 UTC 2016
Pages137
Paragraphs3283
Words41863

Comments