Performance Summary Valve Sample 2B

ASCO Catalogue No. NS83022036

BASELINE TESTING

VALVE SAMPLE NO. 2B ASCO CATALOG NO. NS8302203G TESTING CONDUCTED IN ACCORDANCE WITH QUALIFICATION SPECIFICATION AQS 21691 REV 3 & ASCO TEST PROCEDURE BULLETIN TP-3-046 TEST MEDIUM: AIR

POST

POST

POST

POST

POST

WEAR

RADIATION

SEISMIC

RADIATION

ENVI.

AGING

AGING

DBE

DBE

DBE

INITIAL

ENERGIZED ALLOWED1.5scfh

.5scfh

20cc/min

70cc/min

15cc/min

30cc/min

100cc/min

DE-ENERGIZED ALLOWED1.5scfh

80cc/mi n

.9scfh

1.0scfh

1.2scfh

1.3scfh

.9scfh

ENERGIZED ALLOWED1.5scfh

40cc/mi n

20cc/min

0

0

0

0

DE-ENERGIZED ALLOWED1.5scfh

5cc/min

20cc/min

20cc/min

20cc/min

20cc/min

40cc/min

100 PSIG 100 TO

passed

passed

passed

passed

passed

passed

passed

passed

passed

passed

passed

passed

FILL @__100__PSIG

120ms

140ms

130ms

190ms

130ms

192ms

DISCHARGE @ 100 PSIG

370ms

380ms

350ms

390ms

390ms

396ms

Note 1: External leakage was detected at the lower guide cap/body and end cap/body joint. The leakage was not enough to affect the performance of the valve.

Performance Summary: The valve acceptably performed throughout the qualification program including baseline tests and environmental DBE simulation.

EXTERNAL LEAKAGE @_10 & 100 PSIG (ENERGIZED & DE-ENE

NOISE TEST

SHIFT TIME

RGIZED)

passed

passed

passed

passed

end cap lwr gd cap Note 1

end cap Note 1

SEAT LEAKAGE HIGH

PRESSURE

@

100

PSIG

SEAT LEAKAGE HIGH