X hits on this document

110 views

0 shares

0 downloads

0 comments

27 / 29

Page 27 of 29

Baseline Testing Valve Sample 11C

ASCO Catalog No. NSEL830081F

BASELINE TESTING VALVE SAMPLE NO. 11C ASCO CATALOG NO. NSEL830081F TESTING CONDUCTED IN ACCORDANCE WITH QUALIFICATION SPECIFICATION AQS 21691 REV 3 & ASCO TEST PROCEDURE BULLETIN TP-3-046 TEST MEDIUM: AIR

DE-ENERGIZED ALLOW: 1.5scfh

5cc/min

0

.5scfh

50cc/min

3.0scfh Note 3

.95scfh

OPERATIONAL:_10X @ 150 PSIG 150 TO 0 PSIG

passed

passed

passed

passed

passed

passed

NOISE TEST

passed

passed

passed

passed

passed

passed

SHIFT TIME

FILL @__150__PSIG

.26sec

.28sec

.28sec

.28sec

.28sec

.26sec

DISCHARGE @ 150 PSIG

.66sec

.78sec

.72sec

.74sec

.70sec

.76sec

Performance Summary: During Environmental DBE, while performing cycle 22, the valve vented cylinder pressure. Post Environmental baseline testing with replacement coil and bypassing the module was acceptable.

Note 2: External leakage detected at solenoid base sub-assembly and end cap/body joints. Leakage was not enough to affect performance of the valve.

Note 3: Seat leakage within acceptable limits as defined in AQS21691/R3 - Section 6.2.3.

INITIAL

POST

POST

POST

POST

POST

WEAR

RADIATION

SEISMIC

RADIATION

ENVI.

AGING

AGING

DBE

DBE

DBE

passed

passed

passed

passed

SBSA

Note 2 endcap

Note 2

.6scfh

130cc/min

.7scfh

.5scfh

.5scfh

150cc/min

110cc/min

20cc/min

30cc/min

0

0

5cc/min

5cc/min

0

5cc/min

0

0

0

EXTERNAL LEAKAGE @_10 & 150 PSIG (ENERGIZED & DE-ENERGIZED)

SEAT LEAKAGE HIGH PRESSURE

@

150

PSIG

SEAT LEAKAGE HIGH PRESSURE

@

10

PSIG

ENERGIZED ALLOW: 1.5scfh

DE-ENERGIZED ALLOW: 1.5scfh

ENERGIZED ALLOW: 1.5scfh

Document info
Document views110
Page views113
Page last viewedFri Dec 09 17:26:27 UTC 2016
Pages29
Paragraphs1188
Words7570

Comments