        • 8.

          NFRC 500-2010, “Procedure for Deter- mining Fenestration Product Condensation Resistance Values”

    • 1.05

      System description

      • A.

        Windows:

NOTE TO SPECIFIER: Delete configura- tion option not required.

    • 2.663” frame depth; extruded aluminum with integral nailfin and structural polyurethane thermal break in frame and sash members; finish factory-applied; frames and sash factory-assembled.

  • B.

    Configuration:

    • Single hung (AAMA designation “H”)

    • Horizontal Sliding (AAMA designation “HS”)

    • Fixed (AAMA designation “FW”)

  • C.

    Glazing:

Factory-glazed per Section 2.02F herein

NOTE TO SPECIFIER: Delete configura- tion not required.

with:

    • 2” applied muntins

    • 5/8” flat grid within insulating glass airspace

    • 1” flat grid within insulating glass airspace

  • D.

    Installation: Installation type of: NOTE TO SPECIFIER: Delete configura- tions not required. with:

    • Strap Anchor - Field Applied

    • Panning - Field Applied

    • Snap-trim - Field Applied

    • Custom

B.

    • 1.06

      Performance Requirements: NOTE TO SPECIFIER: Delete those of fol- lowing paragraphs B through E that do not apply to the project requirements.

      • A.

        AAMA Performance Class: NOTE TO SPECIFIER: Delete standard reference, window type and Performance Class not required.

Per AAMA/WDMA/CSA 101/I.S.2/A440-

C.

05, when tests are performed

on

the

minimum test size indicated:

¾

Single hung:

  • -

    H-C50-56X91

¾ Horizontal Sliding:

D.

¾

  • -

    HS-C50-72X60

Fixed:

  • -

    FW-HC50-60X72.

Page 3 of 7

M-85 Spec – Rev. 9/10

Per (NAFS) AAMA/WDMA/CSA 101/I.S.2/ A440-08, when tests are performed on

the minimum test size indicated:

¾

Single Hung:

- CW-PG30-H-56X91 - CW-PG50-H-48X72 (Calculated)

¾

Horizontal Sliding:

¾

- CW-PG35-HS-72X60 Fixed:

  • -

    CW-PG50-FW-60X72

Thermal Performance: 1. Windows shall

NOTE TO SPECIFIER: Delete those op- tions of paragraphs 1 and 2 that do not apply.

  • meet Project requirements of

¾U-value: [SPECIFIER: Enter maxi-

mum permitted requirements]

by

the

project

¾SHGC: [SPECIFIER: Enter maxi-

mum permitted requirement]

by

the

project

2.

Thermal performance to be verified by simulation & testing (Horizontal Slider Only) for conformance with [NOTE TO SPECIFIER: Select any as applicable)]

  • NFRC-100 (determining U-value by

simulation or CMA)

NFRC 102 (determining

U-value by

test) NFRC-200 (determining

SHGC

by

simulation or CMA) NFRC-201 (determining

SHGC

by

test)

  • NFRC-300 (determining solar optical proper-ties by test)

  • NFRC-301 (determining emittance by test)

  • NFRC-400 (determining air infiltration by test)

  • NFRC-500 (determining condensation resistance values by simulation)

(Manufacturer to provide test results on request). Forced Entry Resistance: Shall meet the requirements for AAMA 1302.5 and conform to ASTM F 588 (Grade 40, minimum for fixed). (Grade 10, Minimum for horizontal sliding and hung) Sound transmission (Horizontal Slider & Single Hung Only):

1.

Windows shall requirements of:

meet

Project

  • OITC: [SPECIFIER: Enter job spec]