X hits on this document

22 views

0 shares

1 downloads

0 comments

2 / 4

Description

The Airfin Cooler provides a reliable means of reducing the temperature sur- rounding a mechanical seal, without the use of cooling water.

There are three models of Airfin Coolers. The Model 625 NC operates by means of natural convection. Hot air rises up through the center of the coiled tubing, drawing cool air in from the sides and bottom. The two Model 625 FC units are identical to the above model, except they are equipped with motor driven squirrel cage type blower wheels.

1

Installation

1.1

All models must be mounted in a vertical position, adjacent to and above the seal chamber. The piping, or tubing, to and from the Airfin Cooler should be as short as possible. See Figure 1.

Typical Installation of Airfin Cooler

Airfin Cooler

  • 6-12" Above seal chamber

  • No more than 4' from seal chamber

Cooled Product Outlet

Mounting Bracket

Vent Valve

Hot Product Inlet

Figure 1

1.2

The Airfin Cooler should be mounted in a location where it will be free from all obstructions on the top, bottom, and sides. Failure to do so will result in an appreciable reduction in heat transfer efficiency.

1.3

Please read the complete instructions before starting installation. Be sure you have a copy of the proper Airfin Cooler assembly drawing.

© Copyright 2003 Flowserve Corporation