TABLE 7: STATION A

(1) Near bedroom doorway, appx. 3-5 m from closest section of antenna located above ceiling

14-17

10-14

7-12

(2) Above bedroom doorway near heating/cooling vent (localized) appx. 2-3 m from antenna

19

17-19

17

(3) Near ceiling duct (localized)

38

--

--

(4) Top of hall stairway & almost directly beneath antenna (appx. 1-2 m); localized near smoke alarm

75

30

14-17

(5) Bedroom corner closest to antenna (appx. 2-3 m)

22-24

--

--

(6) Near middle of bedroom

7-10

30

5-12

NOTES:

  • (1)

    Measurements made using Holaday Model HI-3001 field intensity meter.

  • (2)

    Measured values corrected using calibration factors and rounded off.

  • (3)

    Dashes = not measured.

(7) Near bedroom intercom (localized)

--

75-81

--

(8) In hatchway leading to attic (appx. 1-2 m from closest antenna section)

43-97

81-91

22-37

ELECTRIC FIELD STRENGTH: ATTIC-MOUNTED DIPOLE ANTENNA

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14.15 MHz

21.15 MHz

28.15 MHz

(100 W) (100 W)

(100 W)

LOCATION

Electric Field Strength (V/m)

17