EPSON PRODUCT SUPPORT BULLETIN - page 4 / 28

75 views

0 shares

0 downloads

0 comments

4 / 28

If you have firmware version 01.57.7431-0110-0107-0112 or later installed on your viewer then

proceed to the next section. Note: See bulletin PSB.2009.06.003 / PSB.2009.09.002 or PSB.2009.11.001 for upgrading from firmware versions prior to 1.57.

Steps: Install a blank memory card into a memory card reader/writer and copy the “PSV5FIRM” folder (including all the files in the folder) to the root directory of the memory card.

Verify that the battery is installed in the P-6000 or P-7000 viewer.

Connect the AC adapter to the viewer, but do not power it on.

After the firmware file has been copied to the memory card, insert the Compact Flash or SD memory card into the viewer.

Press and hold down the “OK” and

keys while sliding the “POWER” switch as shown below.

Warning: Do not turn off the viewer or attempt to remove the battery or disconnect the AC adapter at any time during the firmware update.

When you see the EPSON logo name, release the OK and will begin and take approximately 4 minutes to complete.

keys; the main firmware update

NOTE: The Sub CPU firmware update is not installed in this version. Do not be alarmed if the Sub CPU firmware update says “is not available….” Once the firmware update is completed you should see this screen.

Page 4 of 6

PSB.2012.01.001