Interim White Paper - Midwest RPO Candidate Control Measures

3/10/2006 Page 12

Michigan – 336.1606 Loading Gasoline into Existing Stationary Vessels & 1703 Loading Gasoline into New Stationary Vessels Ohio – 3745-21- 09 (R) Gasoline Dispensing Facilities

Wisconsin – 420.04 (3) Gasoline Dispensing Facilities

CTG Category: Stage I Vapor Control Systems – Gasoline Service Stations Applicability: Statewide tanks greater than 2,000 gallon capacity at gasoline dispensing facilities Control Requirements:

  • 1)

    submerged fill in tanks at gasoline dispensing facilities handling more than 250,000 gallons per year

  • 2)

    in 38 listed counties, vapor balance system or equivalent capable of returning 90% or more of the vapor to the delivery truck at existing gasoline dispensing facilities handling more than 250,000 gallons per year and for new tanks installed after 7/1/1979 at new or existing gasoline dispensing facilities

Applicability: gasoline dispensing facilities with annual throughputs of 120,000 gallons and greater located in 24 listed counties or anywhere in the State if installed after 10/19/1979 or at facility with potential emissions of 100 tons per year VOC Control Requirements: submerged fill and 90% effective vapor balance or vapor control system Exemptions: floating roof tanks Applicability: counties of Brown, Calumet, Dane, Dodge, Door, Fond du Lac, Jefferson, Kenosha, Kewaunee, Manitowoc, Milwaukee, Outagamie, Ozaukee, Racine, Rock, Sheboygan, Walworth, Washington, Waukesha, and Winnebago Control Requirements: submerged fill and vapor balance or 90% effective vapor control system Exemptions

  • 1)

    tanks less than 575 gallons

  • 2)

    tanks less than 2,000 gallons that were in place prior to 8/1/1979

  • 3)

    tanks with floating roofs or equivalent controls

Other States California – Bay Area – Rule 7 – Gasoline Dispensing Facilities

Applicability: District-wide Control Requirements: submerged fill pipe and “CARB Certified” vapor recovery system (98% volumetric efficiency). Exemptions:

  • 1)

    tanks less than 250 gallons

  • 2)

    agriculture-related (implements of husbandry) tanks less than 550 gallons

Disclaimer: The control measures identified in this document represent an initial set of possible measures. The Midwest RPO States have not yet determined which measures will be necessary to meet the requirements of the Clean Air Act. As such, the inclusion of a particular measure here should not be interpreted as a commitment or decision by any State to adopt that measure. Other measures will be examined in the near future. Subsequent versions of this document will likely be prepared for evaluation of additional potential control measures.