X hits on this document

PDF document

Words in the singular include the plural; and - page 72 / 133

432 views

0 shares

0 downloads

0 comments

72 / 133

SOLID WASTE PROCESSING AND DISPOSAL

CHAPTER 1200-01-07

Rule 1200-01-07-.04, continued)

  • 3.

    The compacted solid waste must be covered at the end of each operating day with an initial cover consisting of at least a six inch layer of compacted soil or an adequate standard of other material as approved by the Commissioner.

  • 4.

    Except for those completed portions to be finally closed (e.g., the final lift), all surfaces which will be left exposed for a period of over thirty days (e.g., initial and intermediate lifts) must be covered by an intermediate cover consisting of at least a one-foot layer of compacted soil or other material approved by the Commissioner.

  • 5.

    All initial and intermediate cover depths must be maintained until either additional wastes are placed over the area or final cover is applied.

  • 6.

    Upon achieving final grade or as otherwise required by the Commissioner, final cover shall be placed as set forth in the closure standards of paragraph (8) of this Rule.

  • (b)

    Class II, Class III, and Class IV Disposal Facilities

    • 1.

      Solid waste disposal activities shall be confined to the smallest practicable area. Compaction will be performed as necessary to ensure a stable fill.

2.

Emplaced solid wastes shall be covered with soil or other material approved by the Commissioner of such depths and at such intervals as the Commissioner deems necessary to prevent fire hazards, promote a stable fill, minimize potential harmful releases of solid wastes or solid waste constituents, and control disease vectors.

Class II disposal facilities sh intermediate cover specified i

all have a frequency and depth of initial and n its permit conditions.

Unless otherwise specified facilities must be covered at inch layer of compacted soil approved by the Commission

by the Commissioner, Class III disposal least once every 14 days with at least a six or an adequate standard of other material as er.

Unless otherwise specified facilities must be covered at inch layer of compacted soil approved by the Commission

by the Commissioner, Class IV disposal least once every 30 days with at least a six or an adequate standard of other material as er.

(i)

(ii)

(iii)

    • 3.

      Upon achieving final grade or as otherwise required, final cover shall be placed as set forth in the closure standards of paragraph (8) of this rule.

  • (7)

    Ground Water Protection/Monitoring Standards

  • (a)

    Class I Disposal Facilities must be designed, constructed, operated, maintained, closed, and cared for after closure such that the following standards are met:

    • 1.

      General Ground Water Protection Standard for solid waste facilities

(i)

This subpart will establish a ground water protection standard for parameters in the facilities’ permits, in Appendix I, and in Appendix II. The ground water protection standard shall be:

May, 2010 (Revised)

72

Document info
Document views432
Page views432
Page last viewedThu Jan 19 02:17:06 UTC 2017
Pages133
Paragraphs5694
Words55007

Comments