Performance Data

Siemens SGT5–PAC 4000F Gas Turbine Package and Combined Cycle Plant

The performance data chart illustrates the application range of the Siemens SGT5-PAC 4000F Gas Turbine Package and the multi-shaft combined cycle plant as a typical application of the package.

Net power output (MW) Net efficiency (%)

Net heat rate (kJ/kWh) Net heat rate (Btu/kWh) Exhaust temperature (°C/°F) Exhaust mass flow (kg/s) Exhaust mass flow (lb/s) Generator type Data at ISO ambient conditions

SGT5-PAC 4000F

SCC5-4000F 2x1 (multishaft)

288 39.5

848 58.5

9,114 8,638 580/1,075 688 1,516 Air-cooled

6,158 5,836