SECTION 09100

METAL SUPPORT ASSEMBLIES

PART 1 - GENERAL

1.01SUMMARY

A.Provisions of Division 01 apply to this section.

B.Section Includes:

1.Metal support systems as indicated and/or described.

C.Related Sections:

1.Section 05410: Load-Bearing Metal Studs.

2.Section 09100:  Top Track Fire-Rated System.

3.Section 09220: Portland Cement Plaster and Metal Lath.

4.Section 09250:  Gypsum Board.

5.Section 09510:  Acoustical Fiber Units

1.02SYSTEM DESCRIPTION

A.Regulatory Requirements:  Comply with DSA and CBC requirements.

B.Design Requirements:

1.Metal Studs: Studs for interior partitions shall be roll-formed channel or C-shapes.

2.Track: Stud track for floor and ceiling anchorage shall be channel configuration, sized to fit studs. Galvanized steel as manufactured for installation with specified metal studs.

3.Design:  Design is based on minimum 5 pounds per square foot load applied perpendicular to walls. Deflection shall not exceed 1/240 under design load.

1.03SUBMITTALS

A.Shop Drawings: Submit drawings showing framing, connection details, accessories and anchorage.  Indicate location of assemblies and size and spacing of framing components.

B.Product Data: Submit manufacturer's catalog data for each item proposed for installation.

C.Certificates:  Furnish manufacturer's certification that materials meet or exceed Specification requirements.

1.04QUALITY ASSURANCE

A.Coordinate with related Work to provide blocking for items mounted on finished surfaces and to provide allowances for pipes and other items inside partitions and walls.

B.Comply with following as a minimum requirement:

1.American Welding Society (AWS):  Structural Welding Code Steel (D1.1); and  Structural Welding Code Sheet Steel (D1.3).