X hits on this document

576 views

0 shares

4 downloads

0 comments

28 / 133

Allen-Bradley ControlLogix Ethernet Driver Help

28

is necessary for the driver to correctly address the I/O. In order to address the I/O in a particular slot, all slots up to and including that slot must be configured with I/O. For example, if a user is only interested in the I/O in slot 3, the I/O for slots 1 and 2 must be configured.

l

Remove: When clicked, this button will remove the selected model from the selected slot.

SLC 500 Modular I/O Selection Guide

The following table lists the number of input and output words available for each I/O module in the Slot Configuration list.

Module Type 1746-I*8 Any 8 pt Discrete Input Module 1746-I*16 Any 16 pt Discrete Input Module 1746-I*32 Any 32 pt Discrete Input Module 1746-O*8 Any 8 pt Discrete Output Module 1746-O*16 Any 16 pt Discrete Output Module 1746-O*32 Any 32 pt Discrete Output Module 1746-IA4 4 Input 100/120 VAC 1746-IA8 8 Input 100/120 VAC 1746-IA16 16 Input 100/120 VAC 1746-IB8 8 Input (Sink) 24 VDC 1746-IB16 16 Input (Sink) 24 VDC 1746-IB32 32 Input (Sink) 24 VDC 1746-IG16 16 Input [TTL] (Source) 5VDC 1746-IM4 4 Input 200/240 VAC 1746-IM8 8 Input 200/240 VAC 1746-IM16 16 Input 200/240 VAC 1746-IN16 16 Input 24 VAC/VDC 1746-ITB16 16 Input [Fast] (Sink) 24 VDC 1746-ITV16 16 Input [Fast] (Source) 24 VDC 1746-IV8 8 Input (Source) 24 VDC 1746-IV16 16 Input (Source) 24 VDC 1746-IV32 32 Input (Source) 24 VDC 1746-OA8 8 Output (Triac) 100/240 VAC 1746-OA16 16 Output (Triac) 100/240 VAC 1746-OB8 8 Output [Trans] (Source) 10/50 VDC 1746-OB16 16 Output [Trans] (Source) 10/50 VDC 1746-OB32 32 Output [Trans] (Source) 10/50 VDC 1746-OBP16 16 Output [Trans 1 amp] (SRC) 24 VDC 1746-OV8 8 Output [Trans] (Sink) 10/50 VDC 1746-OV16 16 Output [Trans] (Sink) 10/50 VDC 1746-OV32 32 Output [Trans] (Sink) 10/50 VDC 1746-OW4 4 Output [Relay] VAC/VDC 1746-OW8 8 Output [Relay] VAC/VDC 1746-OW16 16 Output [Relay] VAC/VDC 1746-OX8 8 Output [Isolated Relay] VAC/VDC 1746-OVP 16 16 Output [Trans 1 amp] (Sink) 24VDC3 1746-IO4 2 In 100/120 VAC 2 Out [Rly] VAC/VDC3 1746-IO8 4 In 100/120 VAC 4 Out [Rly] VAC/VDC4 1746-IO12 6 In 100/120 VAC 6 Out [Rly] VAC/VDC 1746-NI4 4 Ch Analog Input 1746-NIO4I Analog Comb 2 in & 2 Current Out 1746-NIO4V Analog Comb 2 in & 2 Voltage Out 1746-NO4I 4 Ch Analog Current Output 1746-NO4V 4 Ch Analog Voltage Output

Input Words

Output Words

1

0

1

0

2

0

0

1

0

1

0

2

1

0

1

0

1

0

1

0

1

0

2

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

2

0

0

1

0

1

0

1

0

1

0

2

0

1

0

1

0

1

0

2

0

1

0

1

0

1

0

1

0

1

1

1

1

1

1

1

4

0

2

2

2

2

0

4

0

4