All lighting must be at least 2.2m above floor level or protected in an approved way to prevent accidental burning. High-powered lights must be 1 meter away from flammable materials; Lighting and/or lighting equipment intended to be connected to the mains supply must be tested and tagged. To book testing and tagging prior to the show, please contact your show team for details of our electrical contractor; Exhibitions & Events Australia electrical contractors may check lighting and/or lighting equipment on site for compliance. Exhibitors will be required to disconnect lighting and/or lighting equipment that is found to be unsafe or that is not tested or tagged. All lighting and/or lighting equipment must have appropriate certification of Approval (i.e. meet Australian Standards); All lighting and/or lighting equipment must be switched off and disconnected from the mains supply prior to leaving each night. All personnel working at the stand must be informed of the requirements for lighting and lighting equipment.

Electrical Equipment and Electrical Cables:

3 3 3

The use of double adaptors is prohibited – Please use power boards. All cables should be routed away from pedestrian traffic, and taped down to minimise a tripping hazard; All electrical equipment intended to be connected to mains supply must be tested and tagged. To book testing and tagging prior to the show, contact your show team for details of our electrical contractor; Exhibitions & Events Australia electrical contractors may check electrical equipment on site for

3

3 3

compliance. Exhibitors will be required to disconnect electrical equipment found to be unsafe or that is not tested or tagged. Electrical equipment includes power boards, light fittings, computers, appliances, etc. All personnel working at the stand must be informed of the requirements for electrical equipment.

Stand Certification / Structural Integrity

3

Certification is required for stands:

x x x

of two storeys or more - where the second or subsequent storey will be occupied; and/or where the stand has a roof area greater than 18sqm & more than 3m in width; where fire protection requirements are needed = a smoke detector and dry powder-type fire extinguisher;

3

3

3

The onus is on the builder of a stand to prove that the stand is structurally sound, safe for occupancy, and complies with the building code. Detailed plans of the stand, certified by an Engineer, must be lodged with the venue 30 days prior to the opening of the show. The completed stand must be inspected and certified by the exhibitors qualified Engineer.

N a k e d F l a m e s ( i . e . c a n d l e s , i n c e n s e , o i l b u r n e r s , g a s a p p l i a n c e s , e t c ) : A safety barrier is required in front of every lit gas heater; A vigilant stand attendant must be present on the stand at all times; A current/valid fire extinguisher, clearly visible and accessible to visitors, must be kept on your stand; (In addition, consider having a fire blanket on hand); Please ensure that flames are situated so that members of the public cannot come into direct contact with the flame or any surface which may result in burns or cause clothing to ignite; No flammable material shall be within one meter of the flame; Flames must be extinguished 15 minutes prior to the stand being vacated at the end of each day; Proposals for the use of naked flames on stands must be submitted to the venue 30 days prior to the exhibition. All personnel working at the stand must be informed of the requirements for naked flames. 3 3 3 3 3 3 3 3

LP Gas bottles:

3

3 3 3

3 3 3

Where exhibitors intend to use or store LPG or other flammable gas bottles on site, the organisers and the venue must be advised prior to the show. Exhibitors shall be limited to two (2) 9kg cylinders per exhibitor regardless of stand size. LPG fuelled appliances must be installed and tested for leaks by a licensed gas fitter before they are used; Gas cylinders, exposed gas pipes and all connections to the cylinder must be protected from damage at all times; Gas cylinder must be protected by a fire-proof covering at all times (fire blanket); Fire extinguisher, (dry chemical) must be clearly visible at all times. Gas bottles are stored in cages outside the Venue when not in use.