Reactor

Owner

Location

Date Commercial Operation Began

Outage Dates

Reactor Age at Start of Outage (in years)

Outage Length (in years)

NRC Region

Reactor Type

Outage Category

Browns Ferry Unit 2

Tennessee Valley Authority

Athens, AL

3/1/75

9/15/84-5/24/91

9.5

6.7

II

BWR

Safety Restoration

Browns Ferry Unit 3

Tennessee Valley Authority

Athens, AL

3/1/77

3/9/85-11/19/95

8.0

10.7

II

BWR

Safety Restoration

Browns Ferry Unit 1

Tennessee Valley Authority

Athens, AL

8/1/74

3/19/85-?

10.6

21.0 plus

II

BWR

Safety Restoration

Davis-Besse

Toledo Edison Company

Oak Harbor, OH

7/31/78

6/9/85-12/24/86

6.9

1.5

III

PWR

Safety Restoration

Sequoyah Unit 2

Tennessee Valley Authority

Soddy-Daisy, TN

6/1/82

8/22/85-5/13/88

3.2

2.7

II

PWR

Safety Restoration

Sequoyah Unit 1

Tennessee Valley Authority

Soddy-Daisy, TN

7/1/81

8/22/85-11/10/88

4.1

3.2

II

PWR

Safety Restoration

Rancho Seco

Sacramento Municipal Utility District

Clay Station, CA

4/18/75

12/26/85-4/11/88

10.7

2.3

V

PWR

Safety Restoration

Pilgrim

Boston Edison Company

Plymouth, MA

12/1/72

4/11/86-6/15/89

13.4

3.2

I

BWR

Safety Restoration

Peach Bottom Unit 2

Philadelphia Electric Company

Delta, PA

7/5/74

3/31/87-5/22/89

12.7

2.1

I

BWR

Safety Restoration

Peach Bottom Unit 3

Philadelphia Electric Company

Delta, PA

12/23/74

3/31/87-12/11/89

12.3

2.7

I

BWR

Safety Restoration

Nine Mile Point Unit 1

Niagara Mohawk Power Corporation

Lycoming, NY

12/1/69

12/19/87-8/12/90

18.0

2.6

I

BWR

Safety Restoration

Surry Unit 2

Virginia Electric and Power Company

Surry, VA

5/1/73

9/10/88-9/19/89

15.4

1.0

II

PWR

Safety Restoration

Palo Verde Unit 1

Arizona Public Service Company

Tonopah, AZ

1/28/86

3/5/89-7/5/90

3.1

1.3

V

PWR

Safety Restoration

Calvert Cliffs Unit 2

Baltimore Gas & Electric Company

Lusby, MD

4/1/77

3/17/89-5/4/91

12.0

2.1

I

PWR

Safety Restoration

Calvert Cliffs Unit 1

Baltimore Gas & Electric Company

Lusby, MD

5/8/75

5/5/89-10/4/90

14.0

1.4

I

PWR

Safety Restoration

FitzPatrick

New York Power Authority

Scriba, NY

7/28/75

11/27/91-1/23/93

16.3

1.2

I

BWR

Safety Restoration

Brunswick Unit 2

Carolina Power & Light Company

Southport, NC

11/3/75

4/21/92-5/15/93

16.5

1.1

II

BWR

Safety Restoration

Brunswick Unit 1

Carolina Power & Light Company

Southport, NC

3/18/77

4/21/92-2/11/94

15.1

1.8

II

BWR

Safety Restoration

South Texas Project Unit 2

STP Nuclear Operating Company

Bay City, TX

6/19/89

2/3/93-5/22/94

3.6

1.3

IV

PWR

Safety Restoration

South Texas Project Unit 1

STP Nuclear Operating Company

Bay City, TX

8/25/88

2/4/93-2/25/94

4.4

1.1

IV

PWR

Safety Restoration

Walking a Nuclear Tightrope

Table 1. Year-plus Reactor Outages (Listed Chronologically by Outage Start Date) continued

LMFBR = liquid metal fast breeder reactor PWR = pressurized water reactor

BWR = boiling water reactor HTGR = high-temperature gas-cooled reactor

Document info
Document views150
Page views150
Page last viewedTue Dec 06 10:56:49 UTC 2016
Pages47
Paragraphs1517
Words14970

Comments