LC-R061R3PU

6

1.3

3-5

5

Faston 187

35

LC-R121R3PU

12

1.3

3-5

5

Faston 187

36

LC-R122R2PU

12

2.2

3-5

5

Faston 187

40

LC-R063R4PU

6

3.4

3-5

5

Faston 187

42

LC-R123R4PU

12

3.4

3-5

5

Faston 187

43

LC-RB064P

6

4.0

3-5

5

Faston 187 or Faston 250 with hole

44

LC-RB124P

12

4.0

3-5

5

Faston 187 or Faston 250 with hole

45

LC-R064R2P

6

4.2

3-5

5

Faston 187

46

Page

LC-R065P

6

LC-R125P

12

LC-R067P

6

LC-R127P

12

LC-R067R2P

6

LC-R127R2P

12

LC-R0611P

6

LC-R0612P

6

LC-RA1212P

12

LC-LA1233P

12

BATTERY INDEX…FOR MAIN AND STANDBY POWER SUPPLIES Standard Type

5.0 5.0 7.0 7.0 7.2 7.2 11.0 12.0 12.0 33.0

Expected trickle life approx. 3 years…LC-R, LC-L series

Terminal types

Battery-case resin

Flame- Standard retardant (UL94HB) (UL94V-O)

47

  • 

    48

49 50 51 53 55 56 58

  • 64

Model N umbe r

Nominal Voltage (V)

3-5 3-5 3 3 3-5 3-5 3 3-5 3-5 3-5

Rated capacity (Ah) (20 hour rate)

Expected trickle life (years)

at 25°C at 20°C

5 5 5 5 5 5 5 5 5 5

Faston 187 or Faston 250 with hole Faston 187 or Faston 250 with hole Faston 187 or Faston 250 dimple Faston 187 or Faston 250 dimple Faston 187 or Faston 250 with hole Faston 187 or Faston 250 with hole Faston 187 or Faston 250 dimple Faston 187 or Faston 250 with hole Faston 187 or Faston 250 with hole

M6 bolt and nut

Model

Nominal

N umbe r

Voltage

(V)

UP-RW1245P1

12

Nominal Capacity (W)

(10 minute rate) 45W/2V

Expected trickle life (years)

at 25°C at 20°C

3-5

5

Terminal types

Faston 250 with hole

Battery-case resin

Page

(UL94HB)

(UL94V-O)

69

  • (1)

    If used cyclically, so that the battery is repeatedly only partially discharged (by less than 30% of its rated capacity) and then recharged, the battery life may be drastically shortened, depending on the discharging conditions. Please consult Panasonic regarding the actual load pattern, recharging method, environmental conditions, etc.

  • (2)

    Faston 250 with hole only.

  • (3)

    Contact Panasonic for the country of origin on each battery.

LC-T122PU

12

2.0

6

10

Faston 187

LC-TA122PU

12

2.0

6

10

Pressure contact

LC-RD1217P

12

17.0

6

10

M5 bolt and nut

LC-RD1217AP

12

17.0

6

10

M5 threaded post

LC-X1220P

12

20.0 (Nominal capacity)

6

10

M5 bolt and nut

LC-X1220AP

12

20.0 (Nominal capacity)

6

10

M5 threaded post

Flame-

Page

retardant

(UL94V-O)

37

38

59

59

60

60

Terminal types

Battery-case resin

Standard

(UL94HB)

Trickle Long Life Type Expected trickle life approx. 6 years…LC-T series

Model N umbe r

Nominal Voltage (V)

Rated capacity (Ah) (20 hour rate)

Expected trickle life (years)

at 25°C at 20°C

(1)

(2)

If used cyclically, so that the battery is repeatedly only partially drastically shortened, depending on the discharging conditions. conditions, etc. Contact Panasonic for the country of origin on each battery.

discharged (by Please consult

less than 30% of its rated capacity) Panasonic regarding the actual load

and then recharged, the battery life may be pattern, recharging method, environmental

Sealed Lead-Acid Handbook, Page 32