INDIVIDUAL DATA SHEETS

LC-P0612P

For standby power supplies. Expected trickle life: Approx. 6 years at 25°C, Approx. 10 years at 20°C.

Dimensions (mm)

Terminal Type: Faston 187 or Faston 250 with hole

6

151

+

1.5

-

0.5

130.3

5 0 + -

16

1.0 0.5

1.5 0.5

+

-

94

Labels will vary, see page 72 for example of labels.

150.2

0.3

49.2

Specifications

Battery case resin: Flame-retardant (UL94V-0)

Nominal voltage Rated capacity (20 hour rate) Length Width Height Total Height Approx. mass Dimensions

  • *

    The total height of #250 terminal is 101.5mm.

6V 12Ah

151 mm 50.0 mm 94.0 mm 100 mm 2.00 kg

Discharge characteristics (25C) (note)

Terminal voltage (V)

7.2 6.9 6.6 6.3 6.0 5.7 5.4 5.1 4.8 4.5 4.2 3.9

  • 0

    1

2

4

6 8 10

24.0A

20

12.0A

40 60

6.0A

2

3.0A

4

1.2A 0.6A

6 8 10

20

40

(Minute)

(Hour)

Characteristics

Duration of discharge

(note) Capacity (25C)

Internal resistance

20 hour rate (600mA) 10 hour rate (1130mA) 5 hour rate (2080mA) 1 hour rate (8100mA) 1.5 hour rate discharge Cut-off voltage 5.25 V Fully charged battery

(25C)

12.00Ah

    • 11.30

      Ah

    • 10.40

      Ah

    • 8.10

      Ah

    • 5.80

      A

A p p r o x . 1 5 m

Duration of discharge vs. Discharge current

30

20 15

10

(note)

Temperature dependency of capacity (20 hour rate)

Self discharge

(25C)

40C 25C 0C

  • -

    15C

Residual capacity after standing 3 months Residual capacity after standing 6 months Residual capacity after standing 12 months

102 % 100 % 85 % 65 %

91%

82%

64%

Duration of discharge

(Hour)

5 4

3

2 1.5

1 50

40 30

0˚C

  • -

    15˚C

40˚C

25˚C

Charge Method (Constant Voltage)

Trickle use

Initial current

Control voltage

    • 1.80

      A or smaller

    • 6.80

      V to 6.90V

(per 6V cell 25C)

(Minute)

20

10

(Note) The above characteristics data are average values obtained within three charge/discharge. Cycles not the minimum values. (Note) For cycle use of the battery, please contact us in advance.

5

3

300 500 (mA)

1

3

5

10

(A) Discharge current

30

50

100

Sealed Lead-Acid Handbook, Page 57