43 / 236

Interface Operation

Options for the EPILOG Collector

You communicate with the EPILOG collector through a dataset member defined by the RKANPAR DD. Options in the dataset member define the various parameters controlling EPILOG collection. Each option has a default setting. You can change an option in free-form style by using the keywords discussed in Collector keywords.

You can either specify options at startup or change them during a collection interval. If you choose to change options, your new settings take effect at the beginning of the next collection interval (not immediately). The RKANPAR dataset in which you store your options is defined with a record length of 80. The collector reads significant data only from the first 72 bytes of each record. Data entered after column 72 is ignored. Do not specify a record length other than 80, or you might get highly unpredictable results.

Collector Operation

43