Quick-Fill Adapter Installation and Operation**

The Quick-Fill adapter is a device which replaces the standard grease fitting fill port with a high-flow port for use with a standard grease gun.

Step 1: To install the quick-fill adapter, remove the standard fill port located in the front of the pump.

Step 2: Insert the Quick-Fill adapter into the fill port. Hand tighten only.

Step 3: To fill the reservoir, remove the grease gun’s pump head assembly from the container tube (Standard procedure used to install a lubricant cartridge).

Step 4: Insert a new cartridge of grease into the grease gun’s container tube and assemble into the quick-fill adapter.

Step 5: Unlock the follower handle making sure the handle is engaged with the follower. Push the follower rod handle into the container. This action will dispense the entire cartridge of grease into the reservoir. Repeat until the reservoir is full. Replace quick-fill cap.

** This adapter is not a part of the kits, but can be ordered separately (part # 273921).