ECOMESURE

17th april 2008 - Laguna without DPF - NEDC cycle

Laguna without DPF CVS level without any emissions

#/cm3 CVS

  • 0

    200

400

600

800

1000

1200

RS-PMP rack with touch screen panel

RS-PMP response on NEDC cycle for engine without DPF

Technical specifications:

Measurement range Detection limit CPC operation temperature Response time CPC Sample inlet low rate Sampling conditions Dilution ratio range Evaporation tube temperature Evaporation ef iciency

Control

Communication

Sampling Power supply Dimensions

  • 0

    - 20 000 part/cm3 (single count)

0,1 part/cm3 5 - 30°C < 3 sec 5 L/min CVS (dilution tunel) or raw exhaust measurement 100 - 6 000 (DR < 100 under request) 400°C higher than 99% for tetracontane direct rom touched screen panel or with AK-protocole commands RS-232, analog outputs (DR and CPC count), TCP/IP, saved data ile in internal memory rom CVS or tailpipe 220V/50Hz - 2000 W 19" rack with wheels, height 1 800 mm

ECOMESURE B.P. 13 – 3, rue du Grand Cèdre - F 91640 JANVRY Tél. : (+33) 01 64 90 55 55 - Fax : (+33) 01 64 90 55 66 E-mail : contact@ecomesure.com - www.ecomesure.com