Thermocouples options

fittings & Transitions

fittings (T/c and rTd’s)

Transitions ( style f - T/c and rTd’s)

The xed bayonet tting with lockcap provides spring loaded pressure designed for holding probes in place without tapping or drilling. For use with .188” diameter probes only.

Durable stainless tube which allows for the mechanical and elec- trical attachment of the lead wire to the metal sheathed, mineral insulated thermocouple or RTD probe. Standard potting is ep- oxy based and moisture resistant to 500oF. The Hi-Temp potting is ceramic based and good for temperatures to 1100oF. Custom congurations and compounds for extreme temperatures and conditions are also available.

A = Standard Transition w/Relief Spring(500oF)(Std) C = Hi-Temp Transition w/Relief Spring(1100oF)

An Adjustable bayonet compression tting, designed for use with .125” probes, can be positioned at the time of installation. (Available from stock. See page 10)

B = Standard Transition(500oF) D = Hi-Temp Transition(1100oF)

The use of various sealant gland materials allows the compression tting to be repositioned several times after it has been installed. The glands are rated up to 3000 psi and the following temperatures:

M =Mini-Transition (500oF) O = Hi-Temp Mini Transition (1100oF)

*Teon® gland (Standard) (400oF) Neoprene gland (200oF) and Lava Gland (1200oF) Also available.

P = Bolt Transition - Threads toward Tip (500oF) Specify size. Q = Hi-Temp Bolt - Threads toward Tip (1100oF) Specify size.

18

4949 Delemere Ave., Royal Oak, Michigan 48073 Phone (800) 876-4442 Fax (248) 280-0998

Fittings are brazed or welded to the sheath at the time of manufacture. Available in multiple bore sizes, threads (NPT and metric), materials and designs.

one time adj. compression fittings (Stainless Ferrule)

E = Hex Nipple Transition (500oF) Specify size. F = Hi-Temp Hex Nipple (1100oF) Specify size.

G = Bushing - Threads toward Tip (500oF) Specify size. H = Hi-Temp Bushing - Threads toward Tip (1100oF) Specify size.

flanges (T/c and rTd’s)

V = Bolt Transition - Threads toward Leads(500oF) Specify size. W = Hi-Temp Bolt - Threads toward Leads(1100oF) Specify size.

Fittings can be positioned to the exact length at the time of installation. The metal ferrules, brass or stainless, cannot be moved or repositioned once they are installed and compressed.

I = Bushing - Threads toward Leads (500oF) Specify size. J = Hi-Temp Bushing - Threads toward Leads (1100oF) Specify size.

readjustable compression fittings

K = Smooth Transition (500oF) L = Hi-Temp Smooth Transition (1100oF)

GIC can provide any size ange, including custom designs, in large or small quantities. Fixed Flanges can be welded or brazed on. Adjustable anges are also available.

for complete list of sheath fittings, Transitions, Transition potting materials and specifications:

www.GICSensors.com

R = Compression Fitting - Threads toward Leads (500oF) Specify size. S = Hi-Temp Compression Fitting - Threads toward Leads (1100oF)

T = Compression - Double Ended (500oF) Specify size. U = Hi-Temp Compression - Double Ended (1100oF) Specify size.

N = No Transition - Lead wires welded or brazed to sensor Z = Special