new annual license of permit.

120-3-23-.04 Adopted Codes and Standards

(1)

All fire suppression systems required by other rules and regulations of the

Commissioner or by other laws of this state or by local fire safety rules and regulations must be installed, inspected, repaired, recharged, serviced, or tested only be a properly

licensed firm in accordance with the applicable standard (s) of the National Fire Protection Association which are promulgated along with noted modifications as the minimum standards for this state by Chapter 120-3-3.

(2)

All portable fire extinguishers required by other rules and regulations of the

Commissioner or by other laws of this state or by local fire safety rules and regulations must be installed, inspected, repaired, recharged, serviced, or tested only by a properly

licensed firm in accordance with the applicable standard(s) of the National Fire Protection Association which are promulgated along with noted modifications as the minimum standards for this state by Chapter 120-3-3.

120-3-23-.05 Specifications for Service, Maintenance and Test Tags

(1)

(a) It shall be unlawful to install, inspect, recharge, repair, service or test any

portable fire extinguisher or fire suppression system without attaching the required tag or

tags as required by these rules and regulations, or to use a tag not meeting the specifications set forth in these rules and regulations.

(b) It shall be unlawful not to complete the required tag or tags in detail, including the actual month, day and year the work was performed.

(2)

A basic service record tag is required on extinguishers or systems, as required by

the standards adopted by these rules and regulations to have at least an annual service for portable fire extinguisher and semi-annual service for fire suppression systems as per the appropriate NFPA standard. Basic service record tags shall be light yellow in color and shall be at least three (3) inches by five and one-half (5 1/2) inches. A new service record tag shall be attached to the fire extinguisher or fire suppression system by a wire, plastic retainer, or be self adhering when a new extinguisher or system is put into service or each time service is performed. The tags which are affixed directly to the extinguisher shell or

to a system cylinder by adhesion shall be applied to the back of such units so as not to obstruct or interfere with the manufacturers instructions or existing labels. Where a multiple cylinder system is involved, the tag requirements shall apply to each cylinder and control panel where applicable. The following information shall be recorded on the basic service record tag.

(a) Name, street address, mailing address (if different from the street address),