DATAP R O-45™

  • 10.

    Loosen the nut to the point that the probe will turn and, if room permits, align the transition spring and the lead wire at a 90 degree angle from the exhaust pipe. This will position the sender tip correctly in the exhaust stream.

  • 11.

    Tighten the nut back down to secure the probe.

  • 12.

    Attach the thermocouple extension cable to the probe and route the extension cable to the junction box, using tie wraps along the way, but leaving sufficient slack to easily insert the connector into the appropriate junction box jack. Do not harness the cable tightly, being sure to use sweeping bends and loosely guiding the cable to the junction box. This will allow the cable to absorb vibrations along its length

  • 13.

    The cable may be shortened if required. Cut the cable to the desired length (plus some spare) and carefully cut the stainless steel overbraid back approximately 1”. Shrink tubing should be used over the cable where it exits the connector to make for a neater installation. Make certain that the overbraid in no way comes in contact with the wire terminals in the connector. Strip the YELLOW wire back approximately _” and connect to the plus (+) terminal in the connector such as C1. Repeat the process for the RED wire and connect to the negative (-) terminal such as C2. NOTE: Only this wire can be utilized. Substitution of a different wire will affect the operation of the sensor. REMEMBER - The RED wire must be connected to the MINUS (-) terminal and the YELLOW wire must be connected to the POSITIVE (+) terminal.

THERMOCOUPLE INSTALLATION

1 1/4"

Header tube

DETAIL (WELD-IN)

flange

5/16" hole in tube

1/2 tube dia.

Weld-in header adapter Thermocouple compression fitting

Thermocouple probe shaft

Note: check for chassis clearance or other obstructions at desired installation location prior to drilling hole for weld-in header adapter.

        • 1.6.1.2.

          Clamp-In Style Sensor #6037

  • 1.

    Select the header tube in which you wish to mount the sensor.

  • 2.

    Measure a spot 1-_” from the header flange. If more than one cylinder is to be

monitored, it is important that all probes be located the same distance from the header flange. This will allow for comparison from cylinder to cylinder.

Copyright 1999 Computech Systems Inc