DATAP R O-45™

5.8. Record Switch doesn't work

First, make sure that you can start recording by holding down the "START" button on the DATAPRO-45™. If this doesn't work, call your dealer for customer support.

Otherwise, short junction box position B12 directly to chassis ground. If this starts recording, then your problem is with your cable or your switch. You can short the record signal to ground at the far end of the cable, next to the switch. If recording starts, then the cable is good and the problem is with the switch. If recording does not start, then the problem is with the cable.

6. Specifications

Dimensions:

Power Requirements:

LCD Operating Temperature:

LCD Storage Temperature:

Data Sample Rate:

Memory Capacity:

COM/PRT port:

Main unit: 4.5" w, 2.6" h, 1.9" deep, Approx. 6.5 ounces Junction Box (excluding feet): 9” wide, 3.5” high, 1.7” deep, under 24 ounces

11 to 24 volts DC Approximately 200mA

0°C to 50°C (32°F to 122°F)

  • -

    20°C to 70°C (-4°F to 158°F)

100 samples/second standard. Thermocouples 50 samples per second Suspension Sensors 600 samples per second

Estimated 3 minutes recording all channels

Naturally 14,400 Baud, 8 data bits,

2 stop bits, no parity Configurable to standard rates up to

115,000 baud.