X hits on this document

PDF document

February 10, 2006 - page 135 / 238

546 views

0 shares

0 downloads

0 comments

135 / 238

8.6. USING SENSORS IN OPENIPMI

123

00h

- Power off

01h

- Power cycle

02h

- 240VA power down

03h

- Interlock power down

04h

- AC lost

05h

- Soft power control failure (unit did not response to request)

06h

- Failure detected

07h

- Predictive failure. This probably means that the power unit is

still working but may fail soon.

POWER SUPPLY

POWER UNIT

00h - Presence detected 01h - Failure detected 02h - Predictive failure. This probably means that the power supply

is still working but may fail soon. 03h - AC lost 04h - AC lost or out-of-range 05h - AC present but out of range

COOLING DEVICE OTHER UNITS BASED SENSOR MEMORY

DRIVE SLOT POWER MEMORY RESIZE SYSTEM FIRMWARE PROGRESS

Information about the system firmware (BIOS). In an event, the event data 2 may give further information about the error. See section 10.2 for more info.

00h - System firmware error (power-on-self-test error) 01h - System firmware hang 02h - System firmware progress

The sensor is a threshold sensor, but not one specified directly by the

spec.

The units can be fetched with the calls to get the units.

00h 01h 02h 03h 04h 05h

  • -

    Correctable memory error

  • -

    Uncorrectable memory error

  • -

    Parity error

  • -

    Memory scrub failed, probably stuck bit

  • -

    Memory device disabled

  • -

    Reached log limit for correctable memory errors

Document info