  • LUBE PUMP INSTALLATION

WARNING:

Failure to follow the procedures listed below will void the warranty on your pump.

LOCATION:

It is important to determine a desirable place on the vehicle to locate the lube pump. The best location may vary from vehicle to vehicle.

NOTE:

Locate the pump in the upper part of the engine compartment, under the hood. This is important to keep the pump from being exposed to the weather and other harsh elements. .

NOTE:

Mount the pump vertical or horizontal (motor down only) to help insure no water can collect and cause failure. Do not mount in the fender well or behind the bumper. This will void the warranty.

Included in this kit is a pump mounting bracket assembly (p/n 10010047). This allows the pump to be installed on the strut tower, the firewall or the radiator support as examples.

INSTALLATION: (Refer to DIAGRAM 1, page 11)

NOTE:

When routing the 3/8” & 5/16” hoses to the pump, selector valve and pan connector, be sure to route them where road hazards, other moving parts, sharp edges, or hot exhaust parts will not damage them.

Step 1.

The pump is to be mounted in the engine compartment to any suitable flat metal surface. The pump mounting bracket may be used.

Use the four ¼” x 1 ¼” self-tapping metal screws (provided) to mount the pump.

Step 2.

Using a suitable length of 5/16” hose and one of the hose clamps, connect one end of the hose to the output side of the pump.

Step 3.

Route the other end of the 5/16” hose to the selector valve and connect it to the “PUMP” connection of the selector valve.

WARNING:

THE LINE FROM THE PUMP MUST BE CONNECTED TO THE “PUMP” CONNECTION ON THE VALVE.