Summary of Conclusions from the Lloyd’s Report

  • There is potential for escalating failure due to embrittlement - with subsequent explosion/fire

  • Ignition and sustained burn of a vaporized LNG cloud is difficult - multiple ignition sources would probably result in a burn back to the source

  • Unconfined LNG vapor cloud detonation has not been demonstrated and unlikely

  • External ignition (of vapor cloud) results in slow moving flame

  • Rapid Phase Transition will not cause ignition but potentially damaging for ship/equipment