Summary of Conclusions from the Lloyd’s Report

In terms of pool spread

  • The LFL for methane/air mixtures is ~5% so the LFL boundary is well within the visible cloud

  • Modeling of dispersion cloud 3-6 km. Dispersion on that scale unlikely because of local ignition sources

  • Exposure at 300 meters (1000ft) from a pool fire would cause pain within 60 seconds

  • Warming gas cloud will become lighter than air and rise

  • No direct environmental damage or clean up from primary spill

  • A fire fed by single (25,000 m3) cargo tank vented through a 1m2 hole would last 1hr - burn diameter 25 meters

Document info
Document views87
Page views87
Page last viewedSun Dec 11 07:02:55 UTC 2016
Pages30
Paragraphs277
Words1467

Comments