Comparison Sequence.

  • 1.

    Turn ON if greater than activation criterion.

  • 2.

    If not already ON then turn ON if less than activation criterion.

THEN

  • 3.

    Turn OFF if greater than activation criterion.

  • 4.

    If not already OFF then turn OFF if less than activation criterion.

This sequence will ensure that an OFF activation will override an ON activation.

Example 1 To control a thermo fan set the output mode to 4 (Engine Temp.). If you want the fans to turn ON when the engine temperature is greater than 90°C and turn OFF again when the engine temperature is less than 84°C, the auxiliary output parameters should be set as follows:

Mode

4 (Temp activated relay)

Reverse Acting

OFF (Not Ticked.)

ON Above Temp

90 Deg C

ON Below Temp

Off

OFF Above Temp

Off

OFF Below Temp

84 Deg C

As the engine temperature rises, the output remains OFF until it reaches over 90 degrees, the fans will then turn ON and remain ON until the temperature goes below 84 degrees.