SUMMARY OF REQUIREMENTS

The following is a brief summary of the new and revised paragraphs in the Standard for Local Burglar Alarm Units And Systems, UL 609, which have a future Effective Date of March 17, 2007 and the action that may be required to determine compliance.

Paragraphs

General Subject and Comment

1.4, 1.5

The scope has been edited to reflect revised line security designations and associated editorial revisions.

1.7

Reference is made to extent of protection classifications that are based on the Standard for Installation of Burglary and Holdup Alarm Systems, UL 681.  

3.3

Alarm sounding device designations are of two types: Inside or Outside.

A review of existing constructions that utilize these designations may be necessary to confirm continued compliance.   

59.11

Alarm sounding device criteria for mercantile alarm systems was revised / added.

A review of existing constructions that utilize these designations may be necessary to confirm continued compliance.   

61.1, 63.1,

Editorial revisions were made to eliminate grade of service references.

Revision to the product markings and installation instructions may be necessary.

66.1

Editorial revisions were made to bank safe and vault alarm systems, attack test, to coordinate with the elimination of grades of service performance requirements.

Revision to the product markings and installation instructions may be necessary.

67.1

Editorial revisions were made to eliminate grade of service references.

Revision to the product markings and installation instructions may be necessary.

68.2

Editorial revisions were made to bank safe and vault alarm systems, tamper protection, to coordinate with the elimination of grades of service performance requirements.

Revision to the product markings and installation instructions may be necessary.

68.5

Alarm sounding device criteria for bank alarm systems was added.

A review of existing constructions that utilize these designations may be necessary to confirm continued compliance.   

70.1, 71.1, 71.2, 72.1, 72.2

Editorial revisions were made to eliminate grades of service references and associated requirements.

Revision to the product markings and installation instructions may be necessary.

96.2

Marking criteria that clearly identifies the application and signaling function of the product was added.

Revisions to the product markings and installation instructions will be necessary.