NATIONAL PARTITIONS PRODUCT SPECIFICATIONS                   AUGUST 2009

National Partitions, Inc. 10300 Goldenfern Lane, Knoxville, TN 37931

PHONE:  865-670-2100:  FAX:  865-670-2200; WEBSITE:  www.n-p.com

© Copyright 2009, Authorized use is strictly limited to parties writing specifications for National Partitions projects.

fixtures with or without suspended ceiling system.  Include the following  paragraph if lighting fixtures are to be provided as part of wall panel system.  *****

C.Lighting:  Provide ceiling light fixtures as indicated on Drawings and approved shop drawings.

*****  Room lighting level will depend on type of fixture, quantity, and ceiling height.  For a suspended ceiling system, National Partitions typically provides a 24 by 48 inches recessed lay-in fixture with four 32 watt bulbs.  For installation without a suspended ceiling, pendant mounted metal halide fixtures can be provided.  Contact National Partitions for information on other types of available fixture.  Refer to National Partitions product literature for guidelines for calculating required number of lighting fixtures.  *****

1.Type:  [24 by 48 inches recessed troffer, 110 volt, UL listed fixture with four 32 watt fluorescent bulbs producing 3100 lumens per bulb.] [Pendant mounted, 400 watt, metal halide.]

2.Layout:  As indicated on [Reflected Ceiling Plan in Drawings.] [approved shop drawings.]

3.Switches:   Provide single, double, or 3-way grounded, quiet type, UL listed switches to control room lighting as indicated on Drawings and approved shop drawings.  Mount switches 48 inches above floor.

D.Breaker panel:  Provide electrical breaker panel in metal enclosure for prefabricated wall and room system.

*****  Standard breaker panel provided by National Partitions has 4 to 30 circuits.  If larger panel is required for prefabricated room, it must to be provided by others.  *****

1.Type:  [_____] circuits with 20 amps circuit breakers.

2.220 volts air conditioners shall have separate circuit utilizing 2 breakers.

*****  Two options are provided for electrical distribution to outlets, switches, and

light fixtures.  One is a modular, snap together wiring system which only requires a licensed electrician for hook-up of electrical breaker panel to building power source.  Other option is to provide outlets, switches, junction boxes, and rigid conduit extending into ceiling plenum.  With this option, light fixture conduit and all wiring must be provided by licensed electrician.  Include the following paragraph if modular electrical wiring system is being used.  *****  

E.Modular electrical wiring system:  Custom designed, NEC compliant system of modular, interchangeable, UL listed components that snap together as prefabricated room is assembled; Wire-Pak Modular Wiring System as manufactured by National Partitions.

______________________________________________________________________________

PREFABRICATED ROOMS [Using Hi Wall System]13031-F - 13