NATIONAL PARTITIONS PRODUCT SPECIFICATIONS                   AUGUST 2009

National Partitions, Inc. 10300 Goldenfern Lane, Knoxville, TN 37931

PHONE:  865-670-2100:  FAX:  865-670-2200; WEBSITE:  www.n-p.com

© Copyright 2009, Authorized use is strictly limited to parties writing specifications for National Partitions projects.

Standard for Architectural Glazing Materials.

E.International Code Council (ICC):  ICC IBC - International Building Code.

F.International Conference of Building Officials (ICBO):  ICBO UBC - Uniform Building Code (UBC).

1.3SYSTEM DESCRIPTION

*****  Edit the following to reflect project structural design requirements.  *****

A.System shall consist of factory fabricated modular components which can be site erected to form floor-to-roof walls [and interior rooms] of sizes and configuration indicated on Drawings.

B.Erected walls and rooms shall be self-supporting and not require auxiliary structural support other than bracing at roof structure and concrete support slabs.  System shall withstand design loads as required by [ASCE 7] [applicable codes] [_____].

C.System shall be designed and installed to comply with applicable seismic requirements for Project location and Seismic Zone [0] [1] [2A] [2B] [3] [4] as defined by of ICBO/UBC.

D.System shall consist of modular walls panels, base channels, and two-piece post and wall panel connectors which allow for non-progressive assembly.  It shall be possible to interchange or replace panels without removal of adjacent panels.

E.System shall be erected on site with minimum labor, equipment, and time.  Some field cutting and modification may be required for wall panel and roof intersection and other overhead conditions as detailed on Drawings and approved shop drawings.

F.Components shall be factory finished such that field painting is not required.

1.4SUBMITTALS

A.Provide in accordance with Section 01330 - Submittal Procedures:

*****  Edit the following paragraph to indicate if electrical power and lighting fixtures are required.  *****

1.Product data for prefabricated wall and room system, components, accessories, and finishes.  Include data for [electrical power supply] [light fixtures and lighting levels].

*****  Hi Wall System is a pre-engineered system.  Wall system is designed to meet minimum code requirements of 5 PSF lateral load.  For roof system, beams and joists can typically be selected from manufacturer's load tables to meet project requirements.  

______________________________________________________________________________

PREFABRICATED ROOMS [Using Hi Wall System]13031-F - 4