Example: 1 § 0 § means “Enter 1 to specify the function ID, rotate the MCK fully counterclockwise then push Enter briefly, enter 0 to specify the parameter value, then rotate the MCK fully counterclockwise and push Enter momentarily.”

Note 2: Some functions are “on/off” types (value of 0 or 1), while some have a range of values. For example, Function 21's parameter value can range from 15 to 225. In this case the parameter value is shown as a range, e.g., 15225.

Note 3: “Reset” functions have two parameter value options: “Y” for Yes (this is similar to when a PC asks “Are You Sure?”), and “N” for No. To proceed with the reset, push Enter briefly while the Display Matrix shows “Y,” then rotate the MCK fully counterclockwise and push Enter briefly as in Step 7 above.

6.2 Available Functions and Values

Function 1 Value 0 1 2 through12

Instant Access function: Controls startup behavior Result Starts up in Chameleon (sound/Green Bank) mode Starts up with last completed tuning Starts up with corresponding Tune mode (Blue Bank) preset

Default = 1 Clickstream 1§0§ 1§1§ 1 § 212 §

Function 2 Value 0 1

Piezo out mono signal on tip: Set up Piezo out signal Result No Piezo out signal on tip when Piezo pickup is switched on Piezo out signal routed to tip when Piezo pickup is switched on

Note: This relates only to Piezo Out Mono where all six strings are mixed. Piezo Out Hex is never

Default = 1 Clickstream 2§0§ 2§1§ routed to the tip.

Function 4 Value

Inactivity timeout: Determines required inactivity time before shutdown Result

1 through 255

Sets required inactvity time before shutdown (in minutes)

Note: This relates only to Piezo Out Mono where all six strings are mixed. Piezo Out Hex is never

Note: 0 gives fastest tuning with 2.5 cent accuracy, 8 gives slowest tuning with 0.2 cent accuracy

Function 10

Tuning precision: Sets up tuning precision and performance

Value 0 to 8

Result Trades off tuning speed for accuracy. 0 = least accurate, 8 = most accurate

Piezo out mono signal on ring: Set up Piezo out signal Result No Piezo out signal on ring when Piezo pickup is switched on Piezo out signal routed to ring when Piezo pickup is switched on

Functi Value 0 1

on 3

Default = 1 Clickstream 3§0§ 3§1§ routed to the tip.

Default = 10 Clickstream 4 § 1255 §

Default = 5 Clickstream 10 § 09 §

Function 11

Runtime correction: Set up RoboHead runtime correction

Value 0 1

Result Turns off runtime correction (not recommended) Monitoring RoboHeads generates correction data for different string gauges

Default = 1 Clickstream 11 § 0 § 11 § 1 §

Note: It takes up to 10 tunings to match the RoboHead movement to a specific string gauge

Document info
Document views89
Page views89
Page last viewedSun Dec 04 10:14:26 UTC 2016
Pages37
Paragraphs875
Words14062

Comments