Tests Available in the U.S.: CBC, 5-part WBC differential, reticulocytes, NRBCs Throughput: Up to 110 CBC/hr Time to First Result: About 40 seconds Sample Size: 300 mL Frequency of Calibration: Twice a Year Integrated Data Management: Yes Open Reagent System: No Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes What differentiates your product from other products on the market? WBC linearity extends from zero to 400,000; platelet linearity extends from zero to 3 million; consistently accurate WBC, RBC, and platelet counts without manual intervention; advanced auto- verification software; low review rates; performs six-part differentials, including NRBCs; reticulocyte analysis; optional integrated slidemaker/slidestainer; user- defined decision rules help standardize lab processes; remote monitoring and diagnostics technology for increased instrument uptime; backed by the industry’s top-rated service and support. Operational Type: Random access Sample Handling System: Cassettes Number of Reagent Containers Onboard/Tests/Container: Five/varies Walkaway Capacity in Specimen/Tests Assays: Up to 144 samples at one time System Liquid or Dry: Liquid Average Length of System Startup Time and Daily Maintenance: 5-7 minutes

productsusa@drew-scientific.com www.drew-scientific.com Primary Product: Excell 2280 Methodologies Used: Impedance and proprietary laser technology Tests Available in the U.S.: WBC, 5 population differential number and percentage, RBC, HgB, Hct, Mcv, MCH, MCHC, RDW, Plt, MPV Throughput: 80 samples/hour Time to First Result: <1 minute Sample Size: Direct mode 180 uL; sample saver 80 uL Frequency of Calibration: Quarterly Integrated Data Management: Yes Open Reagent System: No Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes What differentiates your product from other products on the market? The 2280 uses multi-dimensional optical scattering using a stable laser diode light source to optimize the measurement of the WBC differential and a patented platelet counting technique to improve the accuracy of platelet counting. Operational Type: Continuous Sample Handling System: 30-position autosampler Number of Reagent Containers Onboard/Tests/Container: 4 reagents Walkaway Capacity in Specimen/Tests Assays: 30 System Liquid or Dry: Liquid Average Length of Daily Startuptime and Daily Maintenance: <5 minutes

Drew Scientific 4230 Shilling Way Dallas, TX 75237 Contact: Frank Matuszak Vice president, Sales and Marketing Telephone: (800) 433-0945 Fax: (214) 210-4949

Mindray Co. Ltd. 8650 154th Ave. NE Redmond, WA 98052 Contact: Ray Xiang Regional Manager Telephone: (425) 881-0361 Fax: (425) 881-0879

«laboratory analyzers buyers guide

»

ray.xiang@mindray.com www.mindray.com Primary Product: BC-3200 Type of Analyzer: 3-part diff hematology analyzer Methodologies Used: Impedance technology Throughput: 60 tests/hour Sample Size: 13 ul whole blood Integrated Data Management: Yes Open Reagent System: Yes Primary Tube Sampling: Yes What differentiates your product from other products on the market? Sampling for either closed or open tube; 4 position tube holder; micro sample size of 13 uL; large color LCD display; data storage of 35,000 samples with histogram

Siemens Medical Solutions Diagnostics 511 Benedict Ave. Tarrytown, NY 10591 Contact: Tina Johne Head Global Communications Telephone: (914) 524-2429 Fax: (914) 524-3693 tina.johne@siemens.com http://diagnostics.siemens.com Primary Product: ADVIA 2120 Hematology Analyzer Tests Available in the U.S.: CBC results: WBC, RBC, HB, HCT, MCV, MCH, MCHC, CHCM, RDW, HDW, CH, CHDW, PLT. Differential results: (absolute and %) NEUT, LYMPH, MONO, EOS, BASO, LUC (Large Unstained Cells). Platelet results: PLT, MPV, PDW, PCT. Reticulocyte results: absolute and % RETIC, MCVr, CHCMr, RDWr**, HDWr**, CHr, CHDWr**. CSF assay results (optional) Throughput: CBC - 120 samples/hr CBC/RETIC - 74 samples/hr CBC/DIFF - 120 samples/ hr RETIC - 74 samples/hr CBC/DIFF - 120 samples/hr RETIC - 74 samples/ hr CBC/DIFF/RETIC - 74 samples/hr Sample Size: 175 uL Integrated Data Management: Yes Positive Sample ID: Yes Walkaway Capacity in Specimen/Tests Assays: Yes

  • Immunoassay

Bayer HealthCare Diagnostics Division 511 Benedict Ave. Tarrytown, NY 10591 Contact: Tina Johne Head Global Communications Telephone: (914) 524-2429 Fax: (914) 524-3693 tina.johne@siemens.com http://diagnostics.siemens.com Primary Product: ADVIA Centaur CP System Type of Analyzer: Random access immunoassay system Methodologies Used: Chemiluminescence Tests Available in the U.S.: Ferritin Folate Vitamin B12 BNP CKMB (CKMB) Troponin (cTnl) Troponin I Ultra (Tnl-Utlra) Homocysteine (HYC) Myoglobin (MYO) Free T4 Free T3 T3 T4 TSH TSH-3 T-Uptake AFP (AFP) CEA (CEA) Complexed PSA (cPsa) PSA Estradiol-6 III FSH LH Progesterone Prolactin Total hCG Testosterone Digoxin Throughput: Up to 180 tests per hour in batch or random access mode Time to First Result: 15 minutes Sample Size: 5 mL, 7 mL, 10 mL, 1mL cups, microtainer tubes Frequency of Calibration: Assay dependent, 3-28 days Integrated Data Management: Yes Open Reagent System: No Primary Tube Sampling: Yes Positive Sample ID: Yes What differentiates your product from other products on the market? Continuous operation, no pause Separation Methodologies: 84 samples, continuous loading in 12-position sample racks Number of Reagent Containers Onboard/Tests/Container: 15 reagents onboard, test per container 50-200, assay dependent Reagents Refrigerated Onboard: Barcode reagent identification, automatic inventory tracking and flagging, calibration validity tracked and flagged, reagent on board residency tracked and flagged, reagent expired/low flags