Sample Handling System:

RACK Number of Reagent Containers Onboard/Tests/Container:

24 assay kits on board/ /200 tests per kit Reagents Refrigerated Onboard:

Yes Walkaway Capacity in Specimen/Tests Assays:

90 specimens/4800 tests-assays System Liquid or Dry:

Liquid Average Length of System Startup Time and Daily Maintenance:

Other Utility Requirements: Deionized Water, Dedicated Electric Line What differentiates your product from other products on the market? Worldwide customer satisfaction, system reliability and performance, Flexibility of configuration to fit laboratory requirements, extensive assay menu (ex: allergy), 15 minute stat cardiac results, on board test capacity of 4800 tests, up to 5 hours of usable walkaway time Internet based service and support with RealTime Solutions (RTS) and OnLine Reports.

4 minute startup; daily maintenance: 5-10 minutes

Operational Type: Continuous Random Access

Primary Product: IMMULITE 2500SMS Methodologies Used: Chemiluminescence Tests Available in the U.S.: Cortisol, AlaTOP, Total IgE, 3gAllergy (IgE specific allergens & allergy panels; includes tests for animals, drugs, dust, foods, grasses, insects, mites, occupational, parasites, trees, weeds), ferritin, EPO, calcitonin, Pyrilinks-D, homocys., hsCRP, insulin, C-peptide, urin. albumin, IGF-I, CMV IgG, rubella IgG/IgM, toxo IgG/IgM, H. pylori IgG, AFP, androst., DHEA SO4, estrad., unconj. estriol, FSH, LH, prolactin, progesterone, testosterone, SHBG, CK-MB, HCG, STAT troponin I, myoglobin, carbamazepine, digoxin, phenytoin, phenobarbital, theophylline, valp.acid, intact PTH, ACTH, α2-microgl., gastrin, hGH, IGFBP-3, herpes I & II IgG, digitoxin, anti-TG Ab, anti-TPO Ab, rapid TSH, 3gen TSH, FT3, TT3, FT4, TT4, T-uptake, thyrogl., BR-MA (CA 15-3), CEA, OM-MA (CA125), PAP, PSA, 3gen PSA (contact company for full menu) Throughput: up to 200 tests/hour Time to First Result: 15 minutes Sample Size: 5 uL Frequency of Calibration: 1-4 weeks (assay dependant) Integrated Data Management: Yes Open Reagent System: No Primary Tube Sampling: Yes Positive Sample ID: Yes Onboard Dilution: Yes

Separation Methodologies: Bead/Centrifugation

Sample Handling System: RACK

Number of Reagent Containers Onboard/Tests/Container: 24 reagents on board/ 200 tests per kit

Reagents Refrigerated Onboard: YES

Walkaway Capacity in Specimen/Tests Assays: 275 specimens/4800 tests-assays

System Liquid or Dry: Liquid

Average Length of System Startup Time and Daily Maintenance:

4 minute Startup/Daily Maintenance: 5-10 minute

Primary Product: WORKCELL

Methodologies Used: Chemiluminescence

Tests Available in the U.S.: Configuration dependent- Please see IMMULITE 2000/2500 menu

Throughput: up to 400/hour

Time to First Result: 15-65 minutes

Sample Size: 17. 5 uL to 100 uL sample

Frequency of Calibration: 1-4 weeks (Assay Dependant)

Integrated Data Management: Yes

Open Reagent System: No

Primary Tube Sampling: Yes

Positive Sample ID: Yes

Onboard Dilution: Yes

Other Utility Requirements: 25. Deionized Water, Dedicated Electric Line

What differentiates your product from other products on the market? Worldwide customer satisfaction, system reliability and performance, flexibility of configuration to fit laboratory requirements , extensive assay menu (ex: allergy), onboard test capacity of 9600 tests, up to 5 hours of usable walkaway time, unique Internet based service and support with RealTime Solutions (RTS) and OnLine Reports.

Operational Type: Continuous Random Access

Separation Methodologies: Bead/Centrifugation

Sample Handling System: RACK

Number of Reagent Containers Onboard/Tests/Container: Varies

Reagents Refrigerated Onboard: YES

Walkaway Capacity in Specimen/Tests Assays: 350 specimens/9600 tests-assays

System Liquid or Dry: Liquid

Average Length of System Startup Time and Daily Maintenance:

4 minute Startup/Daily Maintenance: 10 minutes

Primary Product: IMMULITE 1000

Methodologies Used: Enzyme enhanced chemiluminecse

Tests Available in theU.S.: >80

Throughput: Up to 120 tests per hours

Time to First Result: 15, 42, 65

Sample Size: Assay dependent

Frequency of Calibration: Assay dependent, most 2 weeks

Integrated Data Management: Yes

Open Reagent System: No

Primary Tube Sampling: No

Onboard Dilution: Yes

Other Utility Requirements: DI water

What differentiates your product from other products on the market? Breath of menu

Operational Type: Random and continuous access

Separation Methodologies: Centrifugation

Sample Handling System: Sample cups

Reagents Refrigerated Onboard: Cooled

Walkaway Capacity in Specimen/Tests Assays: .100

System Liquid or Dry: Liquid

Average Length of System Startup Time and Daily Maintenance: ~5 minutes for both

Tosoh Bioscience Inc. 6000 Shoreline Court, Ste. 101 South San Francisco, CA 94080

Contact: Susan Surber Field Marketing Manager Telephone: (800) 248-6764 Fax: (650) 615-0415 susan.surber@tosoh.com www.tosohbioscience.us

Primary Product: Automated Immunoassay Analyzers & HPLC HbA1c Analyzers

Type of Analyzer: Immunoassay

Methodologies Used: Fluorescence, EIA/bead

Tests Available in the U.S.: TSH, 3rd Gen TSH, FT4, T3, T4, TT3, T- Uptake, TPO Ab, Tg Ab, CKMB, Troponin I 2nd Gen, Myoglobin, BHCG, Estradiol, FSH, LH II, Prolactin, Progesterone, Testosterone, AFP, CEA, PSA, CA 125, 27.29, CA 19-9, Ferritin, B12, Folate, Cortisol, C-Peptide, HGH, Insulin, B-2 Microglobulin, IgE II, PAP

Throughput: 36, 60, 180 per hour depending on instrument

Time to First Result: ~18 minutes

Sample Size: 10–100 mL

Frequency of Calibration: 30, 60, 90 days depending on assay

Integrated Data Management: Yes

Open Reagent System: No

Primary Tube Sampling: Yes

Positive Sample ID: Yes

Onboard Dilution: Yes