«laboratory analyzers buyers guide

»

for pre- and post-analytical sample management; automates sample check-in, selectively decaps, sorts, aliquots and archives; processes a variety of tubes and accommodates most analyzer-specific racks Operational Type: Continuous or batch Separation Methodologies: N/A Sample Handling System: Racks/trays Walkaway Capacity in Specimen/Tests Assays: Up to 300 samples in input area System Liquid or Dry: Dry Average Length of System Startup Time and Daily Maintenance: 2 minutes startup; 5 minutes daily maintenance

Siemens Medical Solutions Diagnostics 511 Benedict Ave. Tarrytown, NY 10591 Contact: Tina Johne Head Global Communications Telephone: (914) 524-2429 Fax: (914) 524-3693 tina.johne@siemens.com http://diagnostics.siemens.com Primary Product: ADVIA WorkCell (high-volume chemistry/ immunoassay automation) ADVIA LabCell (fully customizable multidiscipline automation [chemistry; immunoassay; hematology; coagulation; urinalysis]) Throughput: Up to 2,000 tubes per hour (configuration dependent) Integrated Data Management: Yes Positive Sample ID: Yes Onboard Dilution: Yes What differentiates your product from other products on the market? Highest sample throughput currently available; modular; advance intelligent sample process management: automates sample check in; user-defined pre- and post-analytical sample management— sorting and archiving, decapping; centrifugation; automatic rerun, dilution, reflex and test add on capabilities; ability to support parallel processing of any combination of sample tubes. Provides the largest online test menu for primary sample tube processing with the combination of ADVIA Centaur,

ADVIA 1800/2400 and Immulite. Operational Type: Continuous or batch Sample Handling System: Up to 10–100 position barcoded sample racks/sample manager unit Walkaway Capacity in Specimen/Tests Assays: 1000 samples per sample manager (configurable: up to 4 sample managers) Average Length of System Startup Time and Daily Maintenance: Always on: except for once per week 20 minute reboot; <5 minutes daily maintenance

  • Cardiac Diagnostics

Dade Behring 1717 Deerfield Rd. Deerfield, IL 60015

Contact: Amy Boyett Senior Communications Specialist Telephone: (847) 267-5300 Fax: (847) 236-7101 amy_boyett@dadebehring.com www.dadebehring.com

Primary Product: Stratus® CS Acute CareT Diagnostic System

Methodologies Used: Two-site sandwich assay based on solid phase Radial Partition Immunoassay (RPIA) technology

Tests Available in the U.S.: Acute CareT Troponin I, Acute CareT NT-proBNP, Acute CareT Cardiophase® hsCRP, D-dimer, Myoglobin, CKMB, ßhCG

Throughput: 8 tests/hour

Time to First Result: 14 minutes to first result; 4 minutes for each additional

Sample Size: 3 mL whole blood; 200 µL of plasma

Frequency of Calibration: Every new Test Pak lot; for any one lot; 30 days for NT-probNP; 60 days for cTnI, CKMB, Myoglobin, hsCRP and D-Dimer; 90 days for ßhCG

Integrated Data Management: Yes

Open Reagent System:

No Primary Tube Sampling:

Yes Positive Sample ID:

Yes Onboard Dilution:

Yes Other Utility Requirements:

None

What differentiates your product from other products on the market? Designed to fit in various settings: emergency department, stat lab, chest pain center, CCU and ICU; and offers a hsTnI method that meets the ACC/ESC guidelines for Troponin performance (less than or equal to 10% CV at the 99th percentile of a normal reference population). Offers the first high- sensitivity CRP assay cleared by the FDA as an independent marker for risk assessment and for risk stratification in the POC setting. Includes closed container sampling, onboard sample preparation, including centrifugation from the primary collection tube, enabling ease-of-use. Provides stat quantitative results from a whole blood sample within 14 minutes. Results are standardized with the company’s Dimension® family of analyzers in the central lab offering seamless result comparison. This benchtop instrument does not require external water or waste line connections and offers connectivity capabilities to hospital or lab information systems. The Stratus® CS Acute CareT System Kiosk can be purchased as a stand-alone workstation featuring its own lightweight cart, refrigerator and power supply and is uniquely designed for use in the acute care setting. The SCS is compliant with POCT 1A when interfaced with Telcor’s Quick-Linc or MAS’ RALS and optional middleware. The Stratus® CS Acute CareT analyzer is not POCT 1A compliant as a standalone. Operational Type: Continuous random access Separation Methodologies: Radial Partition Immunoassay (RPIA) Number of Reagent Containers Onboard/Tests/Container: Single use Test Paks Reagents Refrigerated Onboard: No Walkaway Capacity in Specimen/Tests Assays: 1/4 System Liquid or Dry: Liquid Average Length of System Startup Time and Daily Maintenance: System check EQC (5 minutes); no daily maintenance

  • Chemistry

Bayer HealthCare Diagnostics Division 511 Benedict Ave. Tarrytown, NY 10591

Contact: Tina Johne Head Global Communications Telephone: (914) 524-2429 Fax: (914) 524-3693 tina.johne@siemens.com http://diagnostics.siemens.com

Primary Product: Clinitek ATLAS; Clinitek Advantus

Type of Analyzer: Clinitek ATLAS: fully automated urine chemistry analyzer; Clinitek Advantus: semi-automated urine chemistry analyzer

Methodologies Used: Drypad measurement; SG by refractive index method

Tests Available in the U.S.: Leukocytes, ketones, protein, glucose, nitrite, occult blood, urobilinogen, pH, bilirubin, color, specific gravity by refractive index method; clarity by measurement of transmitted and scattered light color change measured by reflectance photometry. Dual readings at reactive and reference wavelengths

Throughput: 1 sample every 16 seconds

Time to First Result: Clinitek Advantus: 90 seconds

Sample Size: 2 mL

Frequency of Calibration: With every Reagent Pak change (or every 24 hours when multiple same-lot Reagent Paks used within 24 hours)

What differentiates your product from other products on the market? Clinitek ATLAS: Load 490 tests at one time; continuous reagent roll for high reliability of strip transport; fully automated; walk-away time with Rack Handler up to 53 minutes; Carousel Sample Handler holds up to 50 samples; Rack Sample Handler holds up to 200 samples; liquid level sensing; true calibration of all analytes; accommodates 2 stat samples. Clinitek Advantus: throughput up to 500 tests per hour; color touch-screen display; self-paced sample loading; automatic calibration; microscopy consolidation; one-touch switching between strip types; up to three different user-defined confirmatory flags; one-touch stat interrupt capability

Sample Handling System: Up to 200 samples at one time (up to 20 racks)

Number of Reagent Containers Onboard/Tests/Container: 55 test onboard capacity including ISE

Walkaway Capacity in Specimen/Tests Assays:

Up to 53 minutes